Page 28
remaining exit delay time and make all Stay zones instant, even if they have an entry delay time
programmed.
Option 4 Code required to arm area - If this option is off the partition can be shortcut armed. Shortcut arming
is when the area can be set by pressing the "ARM" key only, i.e. no code is required. If this option is
on, a valid Area "A" user code is required to set the area.
Option 5 Control function requires code - This option determines if a code is required to operate the Control
function. The Control function provides the ability to operate an output from a key press rather than
from an alarm event. If this option is off, pressing the "CONTROL" key will produce an output as
assigned at P291E through P298E option 5. If the option is on, you must press “CONTROL” followed
by a valid code assigned with the control feature to operate the control output.
Option 6 Control function toggles - If this function is enabled, the output which is mapped to the control
function will toggle to the opposite state each time the control function is operated, i.e. if the output is
on it will turn off etc. If the reset time mapped to the control output is zero the output will remain on until
the control function operates again and toggles it off. If there is a reset time mapped to the control
output, the output will turn off at the end of the reset time as expected. The next time the Control
function is operated the output will come on again for the reset period then turn off.
Option 7
Control function is momentary
- If this option is enabled, the output which is mapped to the control
function will turn on for the time period as determined by the value of the pulse timer mapped to the
control output.
Option 8
Control Button disables "Day/Chime" mode or directly Controls Outputs
- If this option is enabled
(LED 8 On), pressing the CONTROL button will put the LED keypads in the special “Control” mode,
indicated by the Control LED turning on. At this point two operations may be performed. The first is that
Outputs can be turned On or Off by selecting the Output number/s required (after first pressing Control)
then pressing the enter button to exit Control mode (for outputs to be controlled at this point option 6 at
P201-P208 must be on). The second option is to press the “Program” button after pressing the
“Control” button which will disable the day alarms for the partition assigned to the keypad. When the
day alarms disable mode is active the CONTROL light will be on. To restore the day function simply
press Control then Program buttons again. A similar set of options are available on the LCD keypad
but to disable day alarms you can either press and hold the “Chime’ button or hold down the Control
button and with 2 seconds also press the Program button to achieve the same result. On the LCD
keypad it shows “Chime Off” when the day alarms are disabled.
If the option is disabled (LED 8 Off) the control button is used to operate the Control Output as
assigned at addresses P291-298, 391-398, 491-498 option 5.
We advise that only one of the Control Function options be assigned at the above address.
Note: P401E is the same as above but applies to Area B Keypad options
Note: P501E is the same as above but applies to Area C Keypad options
PARTITIONS MISC OPTIONS
PARTITION "A" -
P302E
PARTITION "B" -
P402E
PARTITION "C" -
P502E
P302E 1E Key-switch Input enabled
2E Use 2nd Key-switch
3E Key-switch is used for Arm or Stay
4E Pendant chirps on Arming / disarming
5E Pendant chirps on Stay Mode on / off
6E 2 second output on Arming
7E 2 second output on Disarming
8E Access Control enabled even when Area is armed
Option 1
Key-switch Input enabled
- This option will enable the Key-switch input. Operating the Key-switch
input will arm Area "A" as determined by P302E option 3. The Key-switch type is programmed at
P311E options 2, 3 & 4.
Option 2
Use 2nd Key-switch
- This option will enable dual end of line configuration of the Key-switch input and
- - 3 4 - 6 - -
A Misc Options 2