Page 30
restores as they occur. If the option is on, the dialler will send all zone restores only when the
panel is disarmed.
Option 7 Spare
Option 8 Spare
P389E 1-8E Area "B" Reporting Options - (see above for details) Default 1,2
P489E 1-8E
Area "C" Reporting Options
- (see above for details) Default 1,2
PROGRAMMING MISCELLANEOUS
PANEL OPTIONS
P310E
P310E 1E Ignore Mains input
2E Siren tone to Output # 1
3E Siren tone to Output # 2
4E Alert Keypad LEDS off when Armed
5E Ignore Zone tampers during exit delay
6E Installer has direct access to program mode
7E Installer lockout
8E Area "C" zones are shared with Area "A" & "B", i.e. Area "C" zones are common to "A" & "B"
Option 1
Ignore Mains Input -
If the panel must be run off a 12v DC supply only such as a solar
application the 12v can be applied to the battery input and the mains input is ignored.
Option 2 Siren tone to Output # 1 - The alarm panel has an on-board siren driver for driving horn
speakers directly. If this option is On, the panel will drive an 8 ohm horn speaker directly from
output 1. If the option is Off, the output will switch hard to 0v. NOTE: always ensure that this
option is turned on first before connecting a horn speaker to the output otherwise damage will
occur. Also, if the listen-in to output 1 feature is used (P313E) then this option must be turned on
and a horn speaker connected to output 1 for the listen-in feature to work.
Option 3 Siren tone to Output # 2 - The alarm panel has an on-board siren driver for driving horn
speakers directly. If this option is On, the panel will drive an 8 ohm horn speaker directly from
output 2. If the option is Off, the output will switch hard to 0v. NOTE: always ensure that this
option is turned on first before connecting a horn speaker to the output otherwise damage will
occur.
Option 4 Alert Keypad LEDS off when Armed - If this option is on and an Alert Keypad is connected to
the panel, the system LED’s will turn off on the keypad when the alarm is armed. The LED’s will
come back on automatically when an alarm occurs, an entry delay is active, a button is pressed at
the keypad or the system is disarmed.
Option 5
Ignore Zone tampers during exit delay
- If this option is on, any zone tampers created during
the exit delay will be ignored. When the delay expires the zone tampers will be active again.
Option 6 Installer has direct access to program mode - If this option is on, the installer code will allow
access directly to Installer Program Mode provided no areas are armed or in stay mode.
Option 7
Installer lockout
- If this option is on, the installer "Back Door" power up access to program mode
will be disabled. When this option is on the installer code is the only method of accessing installer
program mode.
Option 8 Area "C" zones are shared with Areas "A" & "B" - If the system uses zones which are common
to Area "A" and Area "B" then Area "C" is used for those shared zones. If zones are not shared
between A & B then Area "C" is available as a
independent partition. LED’s on = Shared.
MISCELLANEOUS SYSTEM
Misc Option A
- - - - - 6 - 8
1
2 3 4 - - - -
Misc Option A