Page 54
P434E Radio panic mapped to scenario 1-4 default 1
P435E Test calls mapped to scenario 1-4 default 1
P436E Duress alarm mapped to scenario 1-4 default 1
P437E Supervised radio timeout mapped to scenario 1-4 default 1
P438E Zone inactivity timeout mapped to scenario 1-4 default 1
MULTIPLE ZONE REPORTING
P446E & P466E
P458E
1-8E Zone will report multiple activations for zones 1-8 (Default ON)
P478E 1-8E Zone will report multiple activations for zones 9-16 (Default ON)
PROGRAMMING TEST CALL OPTIONS
P815E - P816E
Because the PW16 runs a real time clock, it is possible to assign test calls by day of the week and time of day rather
than the more common practice of spacing test calls so many hours apart,.
P815E 0-7E Test Call Days of the Week - Where 1 = Sunday and 7 = Saturday. 0 = No Test
P816E XXXXE Test Call Time of Day - Where the time of the day you wish the panel to make its daily test
call is programmed in 24 hour format.
CONTACT ID AREA ACCOUNT CODES
P376E - P378E
P376E XXXXE Account Code for Area "A" Reports - The Account code set at this address will be used to re-
port all system events Arms and Disarms, zone activations, restores and bypasses etc from Area
"A" - Default Account = 0000
P377E
XXXXE
Account Code for Area "B" Reports
- The account code set at this address will be used to re-
port Arms and Disarms, zone activations, restores and bypasses etc from Area "B"
P378E XXXXE Account Code for Area "C" Reports - The account code set at this address will be used to re-
port Arms and Disarms, zone activations, restores and bypasses etc from Area "C"
ZONE CONTACT ID ALARM REPORTING CODE
P721E-P736E
P721E XXXE Zone 1 Activation Default = 130 0 = No Report
P722E XXXE
Zone 2 Activation
Default = 130
P723E XXXE Zone 3 Activation Default = 130
P724E XXXE Zone 4 Activation Default = 130
P725E XXXE
Zone 5 Activation
Default = 130
P726E XXXE Zone 6 Activation Default = 130
P727E XXXE Zone 7 Activation Default = 130
P728E XXXE Zone 8 Activation Default = 130
P729E XXXE
Zone 9 Activation
Default = 130
P730E XXXE Zone 10 Activation Default = 130
P731E XXXE Zone 11 Activation Default = 130
P732E XXXE
Zone 12 Activation
Default = 130
P733E XXXE Zone 13 Activation Default = 130
P734E XXXE Zone 14 Activation Default = 130
P735E XXXE Zone 15 Activation Default = 130
1 2 3 4 5 6 7 8
Test Calls days
Zone 1 Code
130