P375E Command code to turn “MICROPHONE” On Page 45
** Contact ID Account Codes **
P376E Account number for Area "A" - default 0000 Page 54
P377E Account number for Area "B" Page 54
P378E Account number for Area "C" Page 54
Partition “B” Primary Output Options
P381E-P388E OPTIONS
P381E Area "B" primary options for output #1 - Default 1 1 = Standard zone activation's Page 24
P382E
Area "B" primary options for output #2 - Default 1 & 3 2 = Stay Mode activation's Page 24
P383E Area "B" primary options for output #3 - Default 1 3 = Radio key chirps Page 24
P384E Area "B" primary options for output #4 - Default 1 4 = All zones sealed (Ready) Page 24
P385E
Area "B" primary options for output #5 - Default 1 5 = 2 s e c
pulse arm/disarm Page 24
P386E
Area "B" primary options for output #6 - Default 1 6 = Spare Page 24
P387E Area "B" primary options for output #7 - Default 1 7 = Day zone activation's Page 24
P388E Area "B" primary options for output #8 - Default 1 8 = Spare Page 24
** Dialler Reporting Options for partition “B” **
P389E Area B reporting options -Default = 1,2 Page 30
1 = Send set / unset 5 = Send set at the end of the exit delay (LED On)
2 = Send Stay Mode set/unset 6 = Send all zone restores at disarm only
3 = Send unset only after activation's 7 = Spare
4 = Send Stay Mode unset only after alarm 8 = Spare
Programming Partition “B” Parameters
P390E
Time zones used for Area "B" auto arming/disarming - Default 0 Page 26
Partition “B” Specific Output Options
P391E-P398E OPTIONS
P391E Area "B" specific options for output #1 - Default 0 1 =Any exclude Page 25
P392E
Area "B" specific options for output #2 - Default 0 2 = Auto exclude warning Page 25
P393E Area "B" specific options for output #3 - Default 0 3 = Entry beeps Page 25
P394E Area "B" specific options for output #4 - Default 0 4 = Exit beeps Page 25
P395E Area "B" specific options for output #5 - Default 0 5 = Control Page 25
P396E
Area "B" specific options for output #6 - Default 0 6 = Follow Set Arming Page 25
P397E Area "B" specific options for output #7 - Default 0 7 = Follow Stay Arming Page 25
P398E Area "B" specific options for output #8 - Default 0 8 = Follow Unset Page 25
Partition “B” Keypad Options
P399E Arm key can disarm during exit - Default 1-8 Page 26
P400E Stay key can disarm during Stay armed state - Default 1-8 Page 26
Partition “B” Misc Options
P401E Misc partition options 1 - Default 0
1 = Cannot Arm if not sealed Page 27
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required for control
6 = Control toggles
7 = Momentary control