Page 104
Event
Description
Program
Number
Alarm Restore Bypass Un-
Bypass
Trouble Trouble
Restore
Near
Alarm
Verified
Alarm
Burglary 1 BA BH BB BU BT BJ BA BV
Un-typed Alarm 2 UA UH UB UU UT UJ - -
Hold-up 3 HA HH HB HU HT HJ - -
Fire 4 FA FH FB FU FT FJ FA FM
Medical 5 MA MH MB MU MT MJ - -
Panic 6 PA PH PB PU PT PJ - -
Emergency 7 QA QH QB QU QT QJ - -
Gas 8 GA GH GB GU GT GJ - -
Sprinkler 9 SA SH SB SU ST SJ - -
Water 10 WA WH WB WU WT WJ - -
Heat 11 KA KH KB KU KT KJ - -
Freeze 12 ZA ZH ZB ZU ZT ZJ - -
Equipment 13 IA IR - - - - - -
CHART FOR THE PROGRAMMABLE SIA EVENT CODES
Equip. Tamper 14 TA TH TB TU TT TJ - -
When you program one of the numbers in column 2 above at any of the addresses at P196E or P197E then all of the SIA codes
associated with that event type will automatically be loaded, eg if Zone 10 (P196E10E) was programmed with a 4”, then when
zone 10 activates it will send the fire alarm (FA) and the fire alarm restore (FH) and if zone 10 was bypassed it will send the fire
bypass (FB) and the fire un-bypass (FU).