EasyManua.ls Logo

Crow RUNNER 8/64 - Keypads; Keypad Area Assignment

Crow RUNNER 8/64
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 46
will give a pre-alert warning that the area is going to arm. If exit beeps to keypads (P58E) is programmed the keypad
will beep when the pre-alert timer is active. Any zone activity during this time will reset the pre-alert timer and start
the activity timer again. When there has been no zone activity and the pre-alert timer expires the area will begin the
normal exit delay period. During the exit delay arming can only be stopped by entry of a valid user code.
+++++Keypads+++++
KEYPAD AREA ASSIGNMENT
KEYPAD AREA ASSIGNMENT - P71E 1-32E Value = 01-32 for Areas 1-32
Option 01 Area 1” - This option assigns Area 1 to keypads. If a keypad is assigned to only Area 1 it can only Arm
or Disarm that area and will only display zones and area related events for Area 1.
Option 32 Area 32” - This option assigns Area 32 to keypads. If a keypad is assigned to only Area 32 it can only
Arm or Disarm that area and will only display zones and area related events for Area 32.
KEYPAD BUTTON OPTIONS
KEYPAD BUTTON OPTIONS - P72E 1-32E
Option 1 - <CHIME> button Enabled
Option 2 - <BYPASS> button Enabled
Option 3 - Code or Tag can ARM only at this keypad
Option 4 - Code or Tag can STAY ARM only at this keypad
Option 5 - <CONTROL> + <CHIME> Panic Alarm Enabled
Option 6 - <A> + <B> Fire Alarm Enabled
Option 7 - <B> + <CHIME> Medical Alarm Enabled
Option 8 - Stay Armed Beep to Keypad
Option 1 <CHIME> button Enabled - This option enables the <CHIME> button. Chime alarms to the keypad
buzzer and outputs are disabled when Chime is off. If a zone is programmed as a Chime Zone, it can
beep the buzzer on a keypad and/or turn on an output. A typical use of Chime Mode is as a door
minder in a shop. Sometimes it may be desirable to disable Chime mode without the need to reprogram
the panel. This can be achieved by allowing Chime Mode to be disabled with the <CHIME> button on a
keypad. If you press the <CHIME> button on a keypad for 2 seconds (and this option is turned on for
that keypad) the display will show NOCH on the ICON LCD or Chime Mode OFF” on the FULL LCD
keypad. This means that the buzzer will now not sound at the keypad concerned and any Chime Mode
Outputs will not activate. Pressing the <CHIME> button again for 2 seconds will toggle chime mode back
to on again.
Option 2 <BYPASS> button Enabled - This option enables the <BYPASS> button (by keypad number) on any
keypads connected to the panel .
Option 3 Code or Tag can ARM only at this keypad - If this option is turned on the user code or access tag can
full arm the alarm from the keypad. If there is a second keypad connected to the system that keypad can
have this option turned off and option 4 turned on so that the user can stay arm from the other keypad
and fully arm from this keypad using the same code or access tag. For this feature to work the user must
have options 1, 2, 3 & 4 assigned at P4E.
Option 4 Code or Tag can STAY ARM only at this keypad - If this option is turned on the user code or access
tag can arm Stay Mode from the keypad. If there is a second keypad connected to the system that
keypad can have this option turned off and option 3 turned on so that the user can perform a full arm
from the other keypad and Stay arm from this keypad using the same code or access tag. For this
feature to work the user must have options 1, 2, 3 & 4 assigned at P4E.
Option 5 <CONTROL> + <CHIME> Panic Alarm Enabled - This option enables a Panic Alarm to be created
when the <CHIME> + <CONTROL> buttons are pressed simultaneously. NOTE: If a keypad Panic
alarm is generated it will create a separate Panic Alarm for every area assigned to the keypad at
Address P71E. To clear the alarm fully the Panic alarm must be cleared for all areas so the code used to
reset the alarm must be assigned to the same areas (P3E) as the keypad (P71E).
Option 6 <A> + <B> Fire Alarm Enabled - This option enables a Fire Alarm to be created when the <A> + <B>