Option 8 Answer After 1 ring for Listen-in Mode - If this option is turned ON and the optional microphone board
is fitted, the panel will answer an in-coming call after 1 ring and automatically enter listen-in mode.
AUTO-ANSWER RING COUNT
AUTO-ANSWER RING COUNT - P175E 3E (Value 0-99)
If the dialler is set to answer an in-coming call for remote control or upload/download the number of rings before
answering the call can be set at this location. There is also a manual answer function described on page 98.
TEST CALL START TIME
TEST CALL START TIME - P175E 4E (Value 0000-2359)
If the dialler is set to send Automatic Test Calls, the start time for the first call is set at this location. This allows the
test call to be linked to a quiet period where the line would not normally be used (eg 2300)
TEST CALL TIME PERIOD
TEST CALL TIME PERIOD - P175E 5E (Value 0-255 Hours)
When reporting in Contact ID format the panel can send regular test calls to the monitoring company to check the
integrity of the panel and the line. The regularity of the test calls is set at this location. It would normally be set to a
value of 24 so that a test call is sent one a day. The start time for the first test should also be set at location
P175E4E.
KEYPAD LISTEN-IN OPTIONS
KEYPAD LISTEN-IN OPTIONS - P175E 6E
Option 1 - Listen-in Enabled when dialling only and in Disarmed State
Option 2 - Listen-in Enabled when dialling only and in Armed State
Option 3 - Listen-in Enabled when dialling only and in Monitor Mode
Option 4 - Listen-in Enabled through the entire call only in Disarmed state
Option 5 - Listen-in Enabled through the entire call only in Armed State
Option 6 - Listen-in Enabled through the entire call only in Monitor Mode
Option 7 - Listen-in Enabled when the panel answers a call
Option 8 - Listen-in on at All Times
The panel provides the facilities to use the buzzer in the keypad as a speaker to listen to the call being made by the
dialler. To use this feature a 5th wire must be connected between the panel LIN output and a keypad INPUT
terminals. The options above allow many combinations of the listen-in to be used or it can be disabled by selecting
no options. The listen in at a keypad will not work if the keypad input is set up as a zone input at address P122E
option 4.
Dialler Fail Line Switch Output
P175E 7E Dialler Fail Line Switch Output - Value = Output number 1 –32
If no value is entered here the dialler will work as normal. If an output number is programmed at this address and the
dialler fails to get a kiss off after 3 attempts, the programmed output will turn on so it can be used to direct the dialler
to another line source. The dialler will then attempt to connect to monitoring for the balance of the retries
(programmed at address P184E) and the output will remain on until the dialler is kissed off or the retry count has
been reached, at which time the output will turn off again. When the dialler does get through to monitoring it will
report the events that originally triggered the dialler plus a fail to communicate (event 354). If after being directed to
another line source (the programmed output has energised) the dialler still doesnt get kissed off the cycle will repeat.
Every time the output switches on a new fail to communicate event will be generated.
DIALLING PRE-FIX NUMBER
DIALLING PRE-FIX NUMBER - P175E 8E (Value 1-16 digits)