Page 21
ACCESSING PROGRAM MODE
ACCESS TO INSTALLER PROGRAMMING ON POWER UP (INSTALLER MODE)
When power is applied to the controller for the first time and with the panel tamper input open, the panel will in-
hibit tamper alarms and ready the panel to enter INSTALLER PROGRAM MODE (unless the Installer Lock-out at
address P25E10E Option 8 has previously been enabled). At this point you can go to any keypad which is con-
nected to the panel and press <PROGRAM> <ENTER> which will automatically put that keypad into full Program
mode. The LCD will display Installer: USERS(NOTE: Only one keypad can be in Program mode at any time).
ACCESS TO INSTALLER PROGRAM MODE FROM RUN MODE
Before you can enter Installer program mode from normal operating mode, the panel must not be Armed or in Stay
mode (eg completely disarmed). Program mode access is inhibited if any part of the system is Armed.
Press <PROGRAM> - <Installer Code> - <ENTER>
The LCD will display Installer: USERS”
Note: Default Installer Code (P25E1E) is 000000.
You are now in Installer Program Mode. Any program addresses may be viewed or changed in this mode.
ACCESS TO CLIENT PROGRAM MODE FROM RUN MODE
Press <PROGRAM> - <Master User Code> - <ENTER>
The LCD will display Client: USERS”
Note: Default Master User Code is code # 1 (P1E1E) which is 123.
You are now in Client Program Mode. Access to certain program locations is limited while in Client mode (see the
options at address P5E). Each User can have different privileges based on the options assigned to the User at ad-
dress P5E. If no options are set at address P5E for a user, they will not be allowed access to Client program Mode.
RESETTING BACK TO FACTORY DEFAULT SETTINGS (From Install Mode Only)
There are two addresses that allow you to reset the panel back to the factory defaults. The first resets just User
Codes, Installer Code & Telephone Numbers. The Second resets all programming back to the factory Defaults.
e.g. To reset All System defaults:
Press <PROGRAM> - <P200E10E> - <ENTER>
3 short beeps if OK - 1 long beep if error
After the system configuration has been reset back to defaults, all values, options & Codes will be set to the values
shown in the Program Summary as defaults. These values have been chosen as the most common set-up for the
majority of systems.
To reset partial defaults:
Press <PROGRAM> - <P200E9E> - <ENTER>
3 short beeps if OK - 1 long beep if error
The partial reset to defaults will return all User Codes, the Installer Code and Telephone Numbers back to the val-
ues shown in the Program Summary as defaults. These values have been chosen as the most common set-up for
the majority of systems.
TO EXIT PROGRAM MODES USING FULL LCD KEYPAD
There are two ways to exit Program Mode with an LCD keypad. To exit either program mode when you have fin-
ished programming:
Repeatedly press the <PROGRAM> button until the display shows
<ENTER> TO EXIT
Now press <ENTER> to exit Program Mode.,
OR
Press and hold the <PROGRAM> button for 2 seconds to exit program mode