Page 93
Test Call Time Period
P175E 5E Test Time Call Period - Value 0-255 Hours: 0 = No Test (Default = 24) Page 65
Keypad Listen-in Options
P175E 6E Keypad Listen-in Options Page 65
(Default = 1,2,3,4,5,6,7) 1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Stay Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Stay Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Enabled at All Times
Dialler Fail Line Switch Output
P175E 7E Dialler Fail Line Switch Output - Value = Output number 1 –32 Page 66
Dialling Pre-fix Number
P175E 8E Dialling Pre-fix Number - Value 1-16 Digits (Default = 0) Page 66
“Panic” Alarm Contact ID Reporting Code
P175E 9E “Panic” Alarm CID Reporting Code - (Default=120) Page 66
“Fire” Alarm Contact ID Reporting Code
P175E 10E “Fire” Alarm CID Reporting Code - (Default=110) Page 66
“Medical” Alarm Contact ID Reporting Code
P175E 11E “Medical” Alarm CID Reporting Code - (Default=100) Page 66
Output “Command Control” Code Number
P175E 12E Output Command Control code - Value 1-4 digit code (1-9999) (Default = 0) Page 66
Microphone On/Off “Command Control” Code Number
P175E 13E Reserved for future use. Page 67
Dialler Acknowledge Code
P175E 14E Voice/Domestic Acknowledge Code - Value 1-4 digit code (1-9999) (Default = 0) Page 67
Force Test Call Code
P175E 15E Force Test Call Code - Value 1-4 digit code (1-9999) (Default = 0, Feature disabled) Page 67
Programming Voice Board Messages
P176E 1E Keypad or Radio “Panic” Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 2E “Fire” Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 3E “Medical” Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 4E “Mains Failure” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 5E “Mains Restore” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 6E “Battery Low” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 7E “Battery Restored” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 8E “Tamper” (Zone/Radio/System) Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 9E “Duress Alarm” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 10E “Latchkey Disarm” Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 11E “Manual Test Initiated” Voice Message Number - Value 0-99 (Default = 0) Page 67
+++++Telephone Numbers+++++
Programming Telephone Numbers
P181E 1-8E Programming Telephone Numbers - Value 1-16 Digits (Default = 0) Page 68
Telephone Number Reporting Formats
P182E 1-8E Telephone Number Reporting Formats Page 68
(Default = 1) 1 = Contact ID
2 = Domestic Dial
3 = Pager
4 = Speech Dialler
5 = CSV IP Extended (sends 4 digit zone/user field)
6 = Patriot IP
7 = XML IP
8 = CSV IP Normal
9 = Spare
10 = SIA Format
11 = SIA Slow Format