EasyManua.ls Logo

Crow RUNNER 8/64 - Programming Telephone Numbers; Reporting Formats

Crow RUNNER 8/64
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 93
Test Call Time Period
P175E 5E Test Time Call Period - Value 0-255 Hours: 0 = No Test (Default = 24) Page 65
Keypad Listen-in Options
P175E 6E Keypad Listen-in Options Page 65
(Default = 1,2,3,4,5,6,7) 1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Stay Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Stay Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Enabled at All Times
Dialler Fail Line Switch Output
P175E 7E Dialler Fail Line Switch Output - Value = Output number 1 –32 Page 66
Dialling Pre-fix Number
P175E 8E Dialling Pre-fix Number - Value 1-16 Digits (Default = 0) Page 66
Panic Alarm Contact ID Reporting Code
P175E 9E Panic Alarm CID Reporting Code - (Default=120) Page 66
Fire Alarm Contact ID Reporting Code
P175E 10E Fire Alarm CID Reporting Code - (Default=110) Page 66
Medical Alarm Contact ID Reporting Code
P175E 11E Medical Alarm CID Reporting Code - (Default=100) Page 66
Output Command Control Code Number
P175E 12E Output Command Control code - Value 1-4 digit code (1-9999) (Default = 0) Page 66
Microphone On/Off Command Control Code Number
P175E 13E Reserved for future use. Page 67
Dialler Acknowledge Code
P175E 14E Voice/Domestic Acknowledge Code - Value 1-4 digit code (1-9999) (Default = 0) Page 67
Force Test Call Code
P175E 15E Force Test Call Code - Value 1-4 digit code (1-9999) (Default = 0, Feature disabled) Page 67
Programming Voice Board Messages
P176E 1E Keypad or Radio Panic Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 2E Fire Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 3E Medical Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 4E Mains Failure Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 5E Mains Restore Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 6E Battery Low Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 7E Battery Restored Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 8E Tamper (Zone/Radio/System) Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 9E Duress Alarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 10E Latchkey Disarm Voice Message Number - Value 0-99 (Default = 0) Page 67
P176E 11E Manual Test Initiated Voice Message Number - Value 0-99 (Default = 0) Page 67
+++++Telephone Numbers+++++
Programming Telephone Numbers
P181E 1-8E Programming Telephone Numbers - Value 1-16 Digits (Default = 0) Page 68
Telephone Number Reporting Formats
P182E 1-8E Telephone Number Reporting Formats Page 68
(Default = 1) 1 = Contact ID
2 = Domestic Dial
3 = Pager
4 = Speech Dialler
5 = CSV IP Extended (sends 4 digit zone/user field)
6 = Patriot IP
7 = XML IP
8 = CSV IP Normal
9 = Spare
10 = SIA Format
11 = SIA Slow Format