Page 103
SIA Reporting Code Summary
Most of the SIA Event Codes are fixed within the panel but some locations such as zones at P196E (1-64E) and Panic/Fire/
Medical at P197E (1-3E) can have a user defined report code from the table below. To follow are the default SIA reporting codes.
Unlike CID, users 1-2000 will be reported as 1-2000 in SIA format.
Event Type SIA Alarm Code SIA Restore Code
Armed, 24 hour & Near Zone Alarms (programmable P196E) BA BH
Zone Verified Alarm Activated BV BH
Zone Bypassed BB BU
Zone Tamper Activated BT BJ
Sensor-Watch Fail NA NS
Radio Zone Supervise Fail BZ BR
Pendant or Radio Zone Low Battery XT XR
Keypad or Pendant Panic Alarm (programmable P197E1E) PA PH
Keypad Fire Alarm (programmable P197E2E) FA FH
Medical Alarm (programmable P197E3E) MA MH
Duress Alarm HA HH
Panel, Keypad or Wiegand IF-2 Tamper Switch Activated TA TR
Zone Expander Tamper Activated ES EJ
Output Expander Tamper Activated TT TJ
Zone, Output or Wiegand IF-2 fail EM EN
Battery Low (see CID for extension numbers) YT YR
AC Fail (see CID for extension numbers) AT AR
Output Tamper Alarm (O/P 1 & 2 only) YA YH
12V Output (fuse) Failure YP YQ
Phone Line Fail LT LR
Automatic Test Message RP
Manual Test Call RX
Area Delinquency Alarm CD CT
Excessive Code Attempts Alarm JA JP
Armed by User, Pendant, ARM button, DTMF or PC CL OP
Area Armed by Key-Switch CS OS
Area Armed by Time Zone CA OA
Stay Mode Armed by User, Pendant, KS, STAY Button CG OG
Fail to Arm by Time-Zone CI
Program Mode Entry/Exit LB LX
Checksum Fail (Corrupt EEPROM Data) YF
Time Changed JT
Keypad Bus Trouble IA IR
Dialler Failure (No Kiss off) YC
RF Interference (jamming) Detected XQ XH
IP Poll Failure NT NR
Access Door Forced Alarm DF DR
Access Door Left Open too Long DN DH
Egress Door Opened by Pushbutton or Fire alarm DG DY