Option 7 <Control> button can Operate Output - The <Control> button on the keypad can also be used to
turn outputs on or off. For that to happen this option must be turned on for the output/s concerned. To
turn an output on locally at the keypad the operator simply presses the <Control> button for 2
seconds at which time “CTRL” will be displayed on the Icon LCD or the word “Output Control” will be
displayed on the FULL LCD to indicate that the Control mode is active. If any controllable outputs are
currently on they will be indicated at the keypad. The operator can now press a button relating to the
output/s they wish to control eg pressing “01” will turn output 1 on or off, Pressing “32” will turn output
32 on or off, etc. When finished the operator then presses the <ENTER> button to cancel the Control
mode and return to normal.
Option 8 Pulsed Chime Mode Alarm - Chime Zones programmed to this output will turn the output on for the
duration of the Chime to Output time period (P41E). If this option is on the output will pulse at the
pulse timer rate (P39E) for the duration of the chime zone to output timer (P41E).
OUTPUT OPTIONS “B”
OUTPUT OPTIONS “B” - P35E 01-32E
Option 1 - Mains Fail to Output
Option 2 - Fuse Failure to Output
Option 3 - Battery Low to Output
Option 4 - Telephone Line Failure to Output
Option 5 - Supervisory Radio Failure to Output
Option 6 - Sensor-Watch Alarm to Output
Option 7 - System Tamper to Output
Option 8 - Receiver Fail to Output
Option 1 Mains Fail to Output - This option is used to assign a Mains Fail alarm to an Output.
Option 2 Fuse Failure to Output - This option is used to assign a Fuse Failure alarm to an Output. The on-
board fuses are thermally activated. If excessive current is drawn from a fuse it will disconnect the
power until the problem is resolved. There are three thermal fuses protecting the various 12V DC
outputs.
Option 3 Battery Low to Output - This option is used to assign a Battery Low alarm to an Output.
Option 4 Telephone Line Failure to Output - This option is used to assign a Telephone Line Failure alarm to
an Output.
Option 5 Supervisory Radio failure to Output - This option is used to assign a Radio Detector Supervisory
Fail alarm to an Output.
Option 6 Sensor-Watch Alarm to Output - This option is used to assign a Sensor-Watch alarm to an Output.
A Sensor-Watch alarm occurs when a detector has not operated within a set period of time.
Option 7 System Tamper to Output - This option is used to assign a panel or expander tamper alarm to an
Output.
Option 8 Receiver Fail to Output - If the receiver fail timer expires (see P25E7E) this option will assign the
alarm to an Output.
OUTPUT OPTIONS “C”
OUTPUT OPTIONS “C” - P36E 01-32E
Option 1 - Walk-test Pulse to Output
Option 2 - Pulse Output every 5 seconds when Disarmed
Option 3 - Pulse Output on Kiss-off Following Arming
Option 4 - Pulse Output on Kiss-off Following a Zone Alarm
Option 5 - Output Disabled when P25E3E timer is running
Option 6 - Output indicates In-coming phone call
Option 7 - Play Doorbell tone on a Chime zone trigger
Option 8 - IP Fail (Timed)
Option 1 Walk-test Pulse to Output - When the panel is in Walk-test Mode, this option assigns a pulse to the
Output every time a zone is triggered. The pulse is linked to the Output Pulse time (P39E).