assigned to only Area 32 it can only Arm or Disarm that area.
KEYPAD <B> BUTTON AREA OPTIONS
KEYPAD <B> BUTTON AREA OPTIONS - P81E 1-32E
Option 1 - <B> button can Arm
Option 2 - <B> button can Arm A Mode
Option 3 - <B> button can Disarm at All Times
Option 4 - <B> button can Disarm Stay Mode at All Times
Option 5 - <B> button can Reset Alarms
Option 6 - <B> button can Arm Latchkey Mode
Option 7 - <B> button can Disarm During Exit Delay
Option 8 - <B> button can Disarm Stay Mode During Exit Delay
Option 1 <B> button can Arm - This option enables single button Arming using the <B> button. For single button
operation to work options 2 & 3 must be off at location P45E.
Option 2 <B> button can Arm Stay Mode - This option enables single button Arming of Stay Mode using the
<B> button. For single button operation to work options 2 & 3 must be off at location P45E.
(NOTE: Following arming of Stay Mode, if the <ENTER> button is pressed, all entry & exit delays
will be reset to zero for that armed period).
Option 3 <B> button can Disarm at All Times - This option enables single button Disarming using the <B>
button. For single button disarm operation to work options 2 & 3 must be off at location P45E
Option 4 <B> button can Disarm Stay Mode at All Times - This option enables single button Disarming of Stay
Mode using the <B> button. For single button disarm operation to work options 2 & 3 must be off at
location P45E
Option 5 <B> button can Reset Alarms - If this option is On, Pressing the <B> button (provided Option 3 is also
On) will reset an alarm condition without having to enter a user code.
Option 6 <B> button can Arm Latchkey Mode - This option enables single button Arming of the alarm in
Latchkey report mode using the <B> button. For single button Arm operation to work options 2 & 3 must
be off at location P45E. When Latchkey Mode is set on Arming, any code without the Latchkey option
(P4E Option 6) used to Disarm the Alarm will cause a Disarm report to be sent via the dialler.
Option 7 <B> button can Disarm During Exit Delay - This option allows single button Disarming using the <B>
button provided the Armed Mode exit delay is active. If the exit delay has expired the <B> button cannot
be used to disarm the alarm. For single button disarm operation to work options 2 & 3 must be off at
location P45E
Option 8 <B> button can Disarm Stay Mode During Exit Delay - This option allows single button Disarming of
Stay Mode using the <B> button provided the Stay Mode exit delay is active. If the Stay Mode exit delay
has expired the <B> button cannot be used to disarm Stay Mode. For single button disarm operation to
work options 2 & 3 must be off at location P45E
KEYPAD to OUTPUT MASK
KEYPAD to OUTPUT MASK - P82E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
A Keypad can be assigned to an Output or multiple Outputs. If a Keypad is not assigned to an Output a User cannot
turn that Output On or Off from the Keypad. This feature is useful when using the access control features of the
panel, eg a User may be allowed to operate more than one Output with their code but they will be limited to just the
Output assigned to the Keypad they are using.
<CONTROL> BUTTON to OUTPUT MASK
<CONTROL> BUTTON to OUTPUT MASK - P83E 1-32E Value = 01-32 for Outputs 1-32
Option 01 = Output 1 - Option 32 = Output 32
The <CONTROL> button at a Keypad can be assigned to an Output or multiple Outputs. If the <CONTROL> button
is not assigned to an Output a User cannot access Local Control Mode (by pressing the <CONTROL> button) and
turn that Output On or Off from the Keypad. This feature is useful if Outputs are being used to control devices such