Page 59
will retrigger the activity timer only when it unseals. If the zone remains unsealed the activity timer will
not be reset and can expire.
Option 3 Security Interlock Zone - If this option is turned on the zone will be a Security Interlock designed to
monitor a door leading to a room containing a safe or strong-room. It would normally only be
programmed to one area at P121E and that area will be controlled by the “security Interlock zone. If the
“security Interlock zone is unsealed the associated area will be armed. The area can only be disarmed
when the “security Interlock” zone is sealed. The area would be used to control the electronic locking of
the safe or strong-room door by using an output set to follow the disarm state (P49E) of the area. If the
area is armed the electronic door will be locked, if disarmed it will be unlocked
ZONE EOL (End-of-Line) OPTIONS
There are 8 hardwired zone inputs on the panel plus up to 64 zones in total via the input expanders. Each of these
inputs can have different EOL (End-of-Line) configurations if desired. The input can be a short circuit wire loop (Type
0), one of 11 different single resistor values (Types 1-11) or can provide up to 64 zones with tamper (Types 12,13).
Because of the zone input expanders the zone doubling options (Type 14, 15 & 16) are a global option that when set
affect all zones. See chart on page 11 for the resistor combinations and colour codes. NOTE: If using vibration
settings 1-8 (see P126E below) then this location can ONLY be set to type 3.
ZONE EOL (End-of-Line) OPTIONS - P125E 1-64E Value 0-11
Option 0 - Short Circuit Loop Option 8 - 6k8
Option 1 - 1k Option 9 - 10k
Option 2 - 1k5 Option 10 - 12k
Option 3 - 2k2 Option 11 - 22k
Option 4 - 3k3 Option 12 - 2k2 in series with 4k7 (Single zone with tamper)
Option 5 - 3k9 Option 13 - 3k3 in series with 6k8 (Single zone with tamper)
Option 6 - 4k7
Option 7 - 5k6
ZONE RESPONSE TIME
There are 8 hardwired zone inputs on the panel plus up to 64 zones via the zone input expanders. The response time
(how quickly the input responds to an input trigger) can be varied for each zone. The first 8 settings are very fast
response times normally used when vibration sensors are connected to a zone input. Response Settings 1-8
(vibration) can only be applied to zones 1-8 and the zone EOL setting (P125E) must be set to type 3 (2k2).
Zone doubling is not available when vibration settings are used.
The response settings 9-26 start at about 200 ms for setting 9 through to 1.05 sec for setting 26.
ZONE RESPONSE TIME - P126E 1-8E
Response Setting 1 - Highest Vibration setting Response Setting 5 - Middle Vibration setting
Response Setting 2 - Middle Vibration setting Response Setting 6 - Middle Vibration setting
Response Setting 3 - Middle Vibration setting Response Setting 7 - Middle Vibration setting
Response Setting 4 - Middle Vibration setting Response Setting 8 - Lowest Vibration setting
Response Setting 9 - 200 ms Response Setting 18 - 650 ms
Response Setting 10 - 250 ms Response Setting 19 - 700 ms
Response Setting 11 - 300 ms Response Setting 20 - 750 ms
Response Setting 12 - 350 ms Response Setting 21 - 800 ms
Response Setting 13 - 400 ms Response Setting 22 - 850 ms
Response Setting 14 - 450 ms Response Setting 23 - 900 ms
Response Setting 15 - 500 ms Response Setting 24 - 950 ms
Response Setting 16 - 550 ms Response Setting 25 - 1000 ms
Response Setting 17 - 600 ms Response Setting 26 - 1050 ms
ZONE RESPONSE TIME - P126E 9-64E
Response Setting 9 - 200 ms Response Setting 18 - 650 ms
Response Setting 10 - 250 ms Response Setting 19 - 700 ms
Response Setting 11 - 300 ms Response Setting 20 - 750 ms
Response Setting 12 - 350 ms Response Setting 21 - 800 ms
Response Setting 13 - 400 ms Response Setting 22 - 850 ms
Response Setting 14 - 450 ms Response Setting 23 - 900 ms
Response Setting 15 - 500 ms Response Setting 24 - 950 ms
Response Setting 16 - 550 ms Response Setting 25 - 1000 ms