Page 62
Option 01 = Keypad 1 - Option 32 = Keypad 32
If an Area is Stay Mode Armed and a zone assigned to that Area activates, the zone can sound the buzzer at
selected keypads for local alarm signalling. This location assigns zone alarm beep to a keypad for alarms that occur
when in Stay Mode is Armed.
24 HOUR ZONE ALARM BEEPS TO KEYPAD
24 HOUR ZONE ALARM BEEPS TO KEYPAD - P136E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If a zone is programmed as a 24 Hour type and it activates, the zone can sound the buzzer at selected keypads for
local alarm signalling. If the zone is a standard 24 hour type (P123E option 3 on) or Fire type (P123E option 5 on) the
keypad buzzer will sound until reset by a User but if it is an Auto-reset type (P123E option 4 on) the keypad buzzer
will reset when the input clears.
CHIME ZONE ALARM BEEPS TO KEYPAD
CHIME ZONE ALARM BEEPS TO KEYPAD - P137E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If a zone is programmed as a Chime zone and it activates, the zone can sound the buzzer at selected keypads for
local alarm signalling. The duration of the Chime beep is programmed at location P94E. The Chime function can also
be locally disabled at each keypad individually if not required (see P72E option 1 on Page 47 for details).
ZONE TAMPER ALARM BEEPS TO KEYPAD
ZONE TAMPER ALARM BEEPS TO KEYPAD - P139E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If a hardwired zone is programmed to allow tamper monitoring (P125E types 12,13 & 14), or the zone is a radio
detector with tamper, the zone tamper can beep the keypad buzzer at individual keypads.
RADIO SUPERVISE FAIL BEEPS TO KEYPAD
RADIO SUPERVISE FAIL BEEPS TO KEYPAD - P140E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If a zone is programmed as a radio zone and that type is actively monitoring the supervision signal, a supervise
signal failure from the detector alarm can sound the buzzer at selected Keypads for local alarm signalling.
ZONE INACTIVITY ALARM BEEPS TO KEYPAD
ZONE INACTIVITY ALARM BEEPS TO KEYPAD - P141E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If the zone is programmed for inactivity monitoring (P124E option 3 on) and it is not operated within the time set at
P163E a “Sensor-watch” alarm will be generated. A “Sensor-watch” failure from the detector can sound the buzzer at
selected Keypads for local alarm signalling.
ARMED ZONE ENTRY DELAY BEEPS TO KEYPAD
ARMED ZONE ENTRY DELAY BEEPS TO KEYPAD - P142E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If the alarm is Armed and a delay zone triggers the entry delay it can also beep the keypad buzzer to warn that the
entry delay is counting down and the alarm should be turned off.
STAY MODE ENTRY DELAY BEEPS TO KEYPAD
STAY MODE ENTRY DELAY BEEPS TO KEYPAD - P143E 1-64E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32