EasyManua.ls Logo

Crow RUNNER 8/64 - Page 91

Crow RUNNER 8/64
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 91
Armed Zone Entry Delay Beeps to Keypads
P142E 1-64E Armed Zone Entry Delay Beeps to Keypads Page 60
(Default = 1) 01-32 = Armed Zone Entry Delay will Beep Keypad #1-32
Stay Mode Entry Delay Beeps to Keypads
P143E 1-64E Stay Mode Entry Delay Beeps to Keypads Page 61
(Default = 1) 01-32 = Stay Mode Entry Delay will Beep Keypad #1-32
Armed Zone Entry Delay Times
P144E 1-64E Armed Zone Entry Delay Times - Value 0-9999 seconds Page 61
(Default Zone # 1 = 20 Seconds, Zones # 2-64 = 0)
Stay Mode Entry Delay Times
P145E 1-64E Stay Mode Entry Delay Times - Value 0-9999 seconds Page 61
(Default Zones # 1-4 = 20 Seconds, Zones # 5-64 = 0)
Zone Re-trigger Count
P146E 1-64E Zone Re-Trigger Count - Value 0-15 (Maximum number of times a zone can re-trigger Page 61
(Default = 0) during armed state. 0=Unlimited Triggers)
Zone Reports using this Area
P147E 1-64E Zone Reports using this Area - Value 0-32 Page 61
Zone Alarm Contact ID Reporting Codes
P157E 1-64E Zone Alarm Contact ID Reporting Code - (Default = 130) Page 61
Zone Near Alarm Contact ID Reporting Codes
P158E 1-64E Zone Near Alarm Contact ID Reporting Code - (Default = 138) Page 61
Zone Intrusion Verified Alarm Contact ID Reporting Codes
P159E 1-64E Zone Intrusion Verified Alarm Contact ID Reporting Code - (Default = 139) Page 61
Zone Alarm Voice Message Number
P160E 1-64E Zone Alarm Voice Message Number - Value-0-99 (Default = 1) Page 61
Away Zone Entry Delay to Outputs
P161E 1-64E Away Zone Entry Delay to Outputs Page 62
(Default = All Off) 01-32 = Armed Zone Entry Delay to output #1-32
Stay Mode Entry Delay to Outputs
P162E 1-64E Stay Mode Entry Delay Beeps to Outputs Page 62
(Default = All Off) 01-32 = Stay Mode Entry Delay to output #1-32
Sensor-Watch Timer
P163E 1-64E Sensor-Watch Timer - 0-9999 Minutes (Default = 7200 minutes [120 Hours]) Page 62
Enrolling Radio Zone Codes
P164E 1-64E Learn Radio Zone Codes Page 62
Delete a Specific Radio Zone Code
P165E 1-64E Delete a Specific Radio Zone Code Page 62
Find Radio Zone memory Location
P166E ENTER This will find the zone # of any Radio Zone code stored in the panel Page 62
.After P166E press enter to start the find process
Zone Near Alarm to Outputs
P167E 1-64E Zone Near Alarm to Outputs Page 62
(Default = All Off) 01-32 = Zone Near Alarm to output #1-32
Zone Confirmed Alarm to Outputs
P168E 1-64E Zone Confirmed Alarm to Outputs Page 63
(Default = All Off) 01-32 = Zone Confirmed Alarm to output #1-32
Program LCD KP “Zone Name
P169E 1-64E Program LCD KP Zone Name Text Page 63
Access Control Door Monitor Linked to Output
P6174E 1-64E Access Control Door Monitor Linked to Output Page
(Default = All 0) 01-32 = Output #1-32 (0 = Disabled)
Access Control Options
P6175E 1-64E Access Control Options 0 = Disabled, no access monitor options Page
(Default = 0) 1 = Access Door Monitoring
2 = Access Door REX button
3 = Egress button - hold door open
4 = Global Fire Egress - hold all Access doors open
5 = Global Egress - hold all Egress doors open