RUNNER QUICK START GUIDE
The default settings of this panel have been chosen to allow the system to be up and running with a minimum of
programming.
Because of this there are normally only a handful of program addresses that need to be changed to get the
system fully functional.
As a guide to getting the system up and running as quickly as possible we have summarised the most commonly
used addresses for you below.
CODES:
P1E 1-2000E Code 1 is P1E1E and is defaulted to 123. Code 2 is P1E2E, etc up to P1E2000E for code
2000.
ENABLE DIALLER:
P175E 1E By default the Dialler is turned Off. To turn On the dialler you must turn on Option 1 at address
P175E1E.
TELEPHONE NUMBERS:
P181E 1-8E Telephone Number 1 is P181E1E and can be up to 16 digits long. Number 2 is P182E2E, etc up
to P181E8E for Phone number 8.
TELEPHONE FORMAT:
P182E 1-8E There are 9 different reporting formats that can be selected for each telephone number. The
formats are listed on page 108.
ACCOUNT CODE:
P62E 1-32E Area 1 Account code is P62E1E and Area 2 Account code is P62E2E up to P62E32E for Area
32 Account code. Alternatively only Area 1 account code will be used and a group number will
be sent to identify each Area separately (see P183E option 4).
ARMED ENTRY DELAYS:
P144E 1-64E Zone 1 entry delay is P144E1E and can be a value of 0-9999 seconds through to Zone 64 entry
delay being at address P144E64E. A value of 0 makes the zone instant.
STAY ENTRY DELAYS:
P145E 1-64E Zone 1 entry delay when armed in Stay Mode is P145E1E and can be a value of 0-9999
seconds through to Zone 64 Stay Mode entry delay being at address P145E64E. A value of 0
makes the zone instant.
ARMED EXIT DELAY:
P60E 1-32E Area 1 exit delay is programmed at P60E1E, Area 2 at P60E2E and can be a value of 0-255
seconds. A value of 0 makes the area arm instantly with no exit delay.
STAY EXIT DELAY:
P61E 1-32E Area 1 Stay Mode exit delay is programmed at P61E1E, Area 2 at P61E2E and can be a value of
0-255 seconds. A value of 0 arms Stay Mode instantly with no exit delay.