^ Operation
VA 500 Bi-directional English 1.24 Seite 50 von 56
11.4 MBus (optional)
Setup
MBus
11.4.1 Default Settings communication
Primary Adress*: 1
ID: Serialnumber of Sensor
Baud rate*: 2400
Medium*: depending on medium (Gas or Compressed Air)
Manufacturer ID: CSI
VIF coding: Primary VIF
Both addresses, Primary address and ID, could be automatic searched in the M-Bus system.
11.4.2 Default values transmitted
Value 1 with [Unit]*: Consumption [m³]
Value 2 with [Unit]*: Flow [m³/h]
Value 3 with [Unit]*: Gas temperature [°C]
*All Values could be changed / preset in production or with CS Service software (Order-No. 0554 2007)
The Sensor offers two possibilities for coding the
Value Informaition Field (VIF).
Primary VIF (The units and multiplier
correspond to MBus specification 4.8
chapter 8.4.3
Plain text VIF ((units are transmitted as
ASCCII characters. So units that are not
included in MBus specification chapter 8.4.3
are possible
Switch to Plain Text VIF by activation of Units as
String.

Table of Contents

Other manuals for CS Instruments VA 500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CS Instruments VA 500 and is the answer not in the manual?

CS Instruments VA 500 Specifications

General IconGeneral
BrandCS Instruments
ModelVA 500
CategoryAccessories
LanguageEnglish

Related product manuals