This manual must be read before installation, commissioning and maintenance.
Please observe all instructions given in this operating manual. It contains basic information that
must be observed during installation, operation and maintenance.
In addition to these operating instructions, local or national regulations must be observed where
applicable.
Make sure that the VA 500 is only operated within the permissible limits specified on the
nameplate. Otherwise there is a danger to people and material and malfunctions and operating
faults may occur
Improper handling can lead to considerable personal injury and damage to property.
All activities described in this operating manual may only be carried out by qualified personnel
with the qualifications described below
The safety ring attached to the sensor head must always be undamaged and correctly fitted..
The screw-in device must be screwed in pressure-tight.
The clamping sleeve must be tightened with a tightening torque of 20-30 Nm.
In the event of non-observance or non-compliance, the manufacturer cannot be held liable for any
resulting damage. Interventions of any kind on the device, if they do not correspond to the
intended and described procedures, lead to the warranty being voided and to the exclusion of
liability.
The device is intended exclusively for the described purpose.
We do not assume any warranty with regard to the suitability for any particular purpose and no
liability for errors contained in these operating instructions. Nor for consequential damages in
connection with the delivery, performance or use of the device.
Do not exceed the pressure range of 50 bar.
Over 10 bar we recommend using the high-pressure protection for a safe installation.
The installation has to be carried out by authorized professionals
Qualified employees from the measurement and control technology branch should only carry out
adjustments and calibrations
CAUTION
Danger of burns when touching surfaces!
During operation, the components, shaft and connection
nut, can reach a temperature close to the process temperature.
To avoid burns, protection against contact must be ensured at
elevated process temperatures, as there is a risk of medium to
light injuri.
Burnable gases
If this consumption sensor is used for measurement of burnable gases (e.g. natural gas) we
explicitly point out that the sensor has no DVGW (= German Technical Association for Gas and
Water) admission, however, it can be used for natural gas.
A DVGW admission is not mandatory.
The consumption sensor VA 500 corresponds with the latest state of technology and can
generally be used for burnable and non-burnable gases.
The area outside the pipe (environment of the sensor) is not allowed to be an explosive area (Ex-
area)