Total of 60 impacts per unit
Designed to meet the following environments:
Operational Sine over Random Vibration
MIL-STD-810E for AH-1/UH-1 Helicopter in Instrument Panel location
Altitude: sea level to 40,000 feet
Humidity: 0 to 95%, 20 to 55°C
Salt Fog
Sand and dust
Fungus
Explosive atmosphere
EMI/EMC (MIL-STD-461F)
RS101 – Magnetic Field, 30 Hz to 100 kHz
RS103 – Electric Field, 2 MHz to 18 GHz, 200 Volt/meter
CS101 – Power Leads, 30 Hz to 150 kHz
CS114 – Bulk Cable Injection, 10 kHz to 200 MHz, Curve 5.
CS115 – Bulk Cable Injection, Impulse Excitation
CS116 – Damped Sinusoidal Transients, Cables and Power Leads 10 kHz to 100 MHz
CE101 – Power Leads, 30 Hz to 10 kHz
CE102 – Power Leads, 10 kHz to 10 MHz
RE101 – Magnetic Field, 30 Hz to 100 kHz
RE102 – Electric Field, 2 MHz to 18 GHz
Physical
Dimensions and mounting compliant with Military Specification MS25212
Military/aviation rail mounting utilizing Dzus quarter-turn fasteners
Platform mounting utilizing standard L-brackets.
RMC module accessed via environmentally sealed front door with quarter turn locking
mechanism
Data encryption
Elliptical Curve Cryptography (ECC)
AES-256, in-line battery backed-up encryption module for encryption of data-at-rest prior
to storage on RMC module
NIST/FIPS 140-2 certifiable
External encryption key loading
Key may be zeroized by external hardware discrete or by software command
RMC Module
One module individually mounted and accessible
Solid-state storage
Optional capacities from 128 GB to 4 TB per RMC module.
Low insertion/removal force: 40 oz.
High insertion/removal cycle: > 100,000 cycles
Hot insertion/removal
User writeable cartridge/volume name/description (up to 32 characters) stored in cartridge
non-volatile memory accessible via out-of-band interface.
RMC module removal request via front panel push button
LED status indicators:
STATUS (green): on when RMC module is installed, mounted and ready for access
ACTIVITY (green): on when disk is accessed (not supported on some RMC module
configurations)
FAULT (red): DTS1 system monitor has detected a fault with the RMC module