Error 2 - GFX communications issue
Cause:
MCC is receiving incomplete, erroneous, or no information from the Graphics Board that occurred even
after three re-tries.
Service:
If this occurs in Dormant, the cause is likely a software defect or power fluctuation. If this occurs mostly
in active mode, it could be due to static discharge or increased data traffic.
Check internal cabling at the handset to ensure grip leads are not routed close to the back of the
GFX assembly.
Check the cable connections at the embedded power supply in the base. (optional)
Check the cable connections at the 30-pin cable connecting the GFX to the MCC.
Verify the console cable isn’t damaged or pinched anywhere.
Ensure the GFX ground lead is screwed tightly to the GFX case and connected to the MCC’s quick
connect tab.
Page 42 of 202