Cygnus DIVE Operating Manual
M3-DIVE-M-ENG_Iss9.docx
Page 13 of 117
4. Batteries
Important Notes
The battery MUST be fitted BEFORE the DIVE gauge is
immersed into water.
The battery MUST be removed when the DIVE gauge is
no longer being used and/or stored in its Peli case.
The battery MUST NOT be removed while the DIVE
gauge is underwater.
Use in Hyperbaric Conditions
The battery contains lithium and therefore MUST NOT
be taken into a Hyperbaric Condition (IMCA D 041)
Shipping of Lithium Batteries
Please see Section 25 Shipping of Lithium-Ion Batteries on page
110
Fitting the Battery
Smear some Silicone Grease on the face of
the battery. This will help lubricate and
seal battery contacts and screw threads.
Align the battery and push fully into the
battery compartment in the side of the
DIVE gauge body. There is a locating
feature that ensures the battery is
correctly aligned before the electrical
contacts mate.
The gauge will then turn on.