Piping Diagrams
Piping Diagrams
55
Piping
Diagrams
No. Part Name Function
Compressor
This compressor sucks in and compresses low-temperature
and -pressure gas refrigerant generated by evaporator to
make it into high-temperature and -pressure liquid refrigerant.
Condenser
Used to make the high-temperature and -pressure
gas refrigerant generated by the compressor to turn
to high-temperature and -pressure liquid state.
Fan (for condenser)
Used to accelerate heat exchange with the refrigerant
in the condenser by forcible blowing.
Electronic expansion valve for main circuit (EEV)
The valve mechanism reduces pressure of the
high-temperature, high-pressure liquid refrigerant
produced in the condenser, to produce low-
temperature, low-pressure liquid/gas mixed
refrigerant.
Motor operated valve for hot gas (MOV)
This valve controls cooling capacity under low load by
bypassing refrigerant from the high pressure side to
the low one.
Evaporator
Used to make low-temperature, low-pressure liquid
refrigerant decompressed through the electronic
expansion valve into low-temperature and -pressure
gas by heat exchange and evaporation with oil.
Oil pump
Used to draw oil from the unit outside and discharge it
to the outside through the evaporator.
Relief valve
The relief valve controls the outlet side pressure to
the specified level.
Rubber hose
This is the portion of the oil piping used on the
discharge side of the oil pump.
Air filter
This filter is installed in front of the evaporator to
prevent drop of cooling capacity caused by dust
attached to the condenser by drawn air.
Oil drain (evaporator)
The evaporator oil can be discharged from this oil
drain for maintenance of the oil cooling unit.
Oil drain (drain pan)
Used to drain oil from the bottom of the oil cooling
unit.
Circuit breaker ("-B" only)
The circuit breaker activates in case of overcurrent to
protect the wiring system in the unit.
High pressure switch ("-C" only)
In order to protect the refrigerant system in the
compressor, it activates in case of high-pressure error.
Compressor protection thermostat
In order to protect the compressor, it activates in case
of high-pressure error of the compressor.
Heater ("-H" only)
Used to heat oil to the temperature preset by the
electric heater at warm-up in winter.
Oil tank ("-T" only)
It receives oil in the oil piping system with the main
machine, and deals with fluctuations in oil level.
Transformer ("-048" only) Intended for the different-voltage model.