49
PIM00504
Item Code Name Operation range
Default
Value
Details Reference
P10 L_TI
PQ integration
time correction
factor
1 - 500 [%] 100
Sets the integration time correction
factor for PQ control. The smaller
the value, the faster the response,
but the more surge pressure occurs.
-
P11 M_VR
(Reserved for the
system)
- - This is reserved for the system. -
P12 W_TM
(Reserved for the
system)
- - This is reserved for the system. -
P13
PL.0 Pressure setting
4 MPa
specifi-
cations
1.5 - 4.0 [MPa] 1.5
Sets the target pressure.
12.3
22 - 58
58
[×10 PSI]
7 MPa
specifi-
cations
1.5 - 7.0 [MPa] 1.5
22 - 101
[×10 PSI]
101
QL.0 Flow rate setting
14 L
specifi-
cations
2.5 - 15.2
[L/min]
15.2
Sets the target flow rate.
25 L
specifi-
cations
3.5 - 25.1
[L/min]
25.0
30 L
specifi-
cations
3.5 - 28.5
[L/min]
28.5
P14 -
P28
(Reserved for the
system)
- - This is reserved for the system. -
P29 C_TM
(Reserved for the
system)
- - This is reserved for the system. -
P30 DF_N
(Reserved for the
system)
- - This is reserved for the system. -
P31 P_SN
Pressure sensor
rated value
1 - 35 [MPa] 10
Sets the rated pressure of the
pressure sensor. Normally, this
setting does not need to be
changed.
-
P32 S_TM
Surgeless start
time
0.01 - 9.99 [sec] 0.50
Sets the start-up time for a start with
the motor at a stop. Increasing the
value makes the start-up smoother
and can prevent start-up surge, but
it lengthens the response time at
start-up.
12.7.2
P33 L_IN
(Reserved for the
system)
- - This is reserved for the system. -
P34 E_TM
(Reserved for the
system)
- - This is reserved for the system. -
P35 DR_L
Dry operation
judgment
pressure
0.00 - 2.00 [MPa] 0.50
Sets the pressure condition for
judging “E64: Dry operation error”.
12.6.1
0 - 290 [PSI] 72
P36 DR_T
Dry operation
judgment time
0.01 - 9.99 [sec] 3.00
Sets the time for judging “E64: Dry
operation error”.
12.6.1

Table of Contents