13.2 Warning Causes and Corrective Actions
Warning
Code
Name Cause Corrective Action
L44
Motor abnormal
temperature warning
The motor temperature
exceeded the stipulated
value of 83°C for 10
seconds or longer.
The motor cooling fan has
stopped.
Replace the fuse for the fan.
Replace the cooling fan.
Replace the controller.
Replace the fan harness.
The radiator is clogged.
Clean or replace the radiator.
The motor rotation speed
has risen.
Check if the amount of oil
leaking from the circuit at the
main machine has increased.
Review the setting of the high-
pressure safety valve.
Replace the motor pump.
The ambient temperature
is too high.
Install the unit at a location
where the ambient temperature
is within the stipulation.
Install the unit in a location with
good ventilation.
L45
Abnormal temperature
at radiation fin.
The radiating fin
temperature exceeded
the stipulated value of
108°C for 10 seconds or
longer.
The cooling fan has
stopped.
Replace the fuse for the fan.
Replace the cooling fan.
Replace the controller.
The radiator is clogged.
Clean or replace the radiator.
The motor rotation speed
has risen.
Check if the amount of oil
leaking from the circuit at the
main machine has increased.
Review the setting of the high-
pressure safety valve.
Replace the motor pump.
The ambient temperature
is too high.
Install the unit at a location
where the ambient temperature
is within the stipulation.
Install the unit in a location with
good ventilation.
L48
Abnormal temperature
at PCB
The PCB temperature
exceeded the stipulated
value of 68°C for 10
seconds or longer.
The cooling fan has
stopped.
Replace the fuse for the fan.
Replace the cooling fan.
Replace the controller.
The radiator is clogged.
Clean or replace the radiator.
The motor speed has
risen.
Check if the amount of oil
leaking from the circuit at the
main machine has increased.
Review the setting of the high-
pressure safety valve.
Replace the motor pump.
The ambient temperature
is too high.
Install the unit at a location
where the ambient temperature
is within the stipulation.
Install the unit at a location with
good ventilation.