EasyManua.ls Logo

Dalsa Piranha 2 Series - 3.19 Rebooting the Camera

Dalsa Piranha 2 Series
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41 Piranha 2 Users Manual
03-032-00493-14 Teledyne DALSA
Example: disable EXSYNC presence
wed 3 0
Temperature Measurement
The temperature of the camera can be determined by using the vt command. This
command will return the temperature inside the cover in degrees Celsius. For proper
operation, this value should not exceed 75°C.
Voltage Measurement
The command vv checks the cameras inpu t voltage and internal voltages d u ring p ow er -
up. If they are within the proper range, the camera returns OK>. Otherwise the camera
returns an error message. Note that the voltage measurement feature of the camera
provides only approximate results (typically within 10%). They should not be used to set
the applied voltage to the camera. The purpose of this test is to isolate gross problems
with the supply voltages.
3.19 Rebooting the Camera
The command rc reboots the camera. The camera starts up with the last saved settings.
Previously saved pixel coefficients are also restored.
3.20 Setting the Pre-trigger
A pre-trigger may be required for some frame grabbers.
To set the pre-trigger, use the command:
Syntax:
sp i
Syntax Elements:
i
Pretrigger value from 0 to 15.
Example:
sp 10
All manuals and user guides at all-guides.com
all-guides.com

Table of Contents

Related product manuals