2-20 Release Brake Current
Range: Function:
0.00 A
*
[0.00 - par. 16-37] Set the motor current for release of the mechanical brake, when
a start condition is present. The upper limit is specified in par.
16-37
Inv. Max. Current
.
2-21 Activate Brake Speed [RPM]
Range: Function:
0 RPM
*
[0 - 60.000] Set the motor speed for activation of the mechanical brake,
when a stop condition is present. The upper speed limit is speci-
fied in par. 4-53
Warning Speed High
.
2-22 Activate Brake Speed [Hz]
Range: Function:
0 Hz
*
[0 - 5000] Set the motor frequency for activation of the mechanical brake,
when a stop condition is present.
2-23 Activate Brake Delay
Range: Function:
0.0 s
*
[0.0 - 5.0 s] Enter the brake delay time of the coast after ramp-down time.
The shaft is held at zero speed with full holding torque. Ensure
that the mechanical brake has locked the load before the motor
enters coast mode. See
Mechanical Brake Control
section in the
Design Guide.
2. How to Programme FC 300 Programming Guide
68