8-54 Reversing Select ExpressionLimit All set-ups TRUE - Uint8
8-55 Set-up Select [3] Logic OR All set-ups TRUE - Uint8
8-56 Preset Reference Select [3] Logic OR All set-ups TRUE - Uint8
8-7* BACnet
8-70 BACnet Device Instance 1 N/A 1 set-up TRUE 0 Uint32
8-72 MS/TP Max Masters 127 N/A 1 set-up TRUE 0 Uint8
8-73 MS/TP Max Info Frames 1 N/A 1 set-up TRUE 0 Uint16
8-74 "I-Am" Service
[0] Send at power-
up 1 set-up TRUE - Uint8
8-75 Initialisation Password ExpressionLimit 1 set-up TRUE 0 VisStr[20]
8-8* FC Port Diagnostics
8-80 Bus Message Count 0 N/A All set-ups TRUE 0 Uint32
8-81 Bus Error Count 0 N/A All set-ups TRUE 0 Uint32
8-82 Slave Messages Rcvd 0 N/A All set-ups TRUE 0 Uint32
8-83 Slave Error Count 0 N/A All set-ups TRUE 0 Uint32
8-84 Slave Messages Sent 0 N/A All set-ups TRUE 0 Uint32
8-85 Slave Timeout Errors 0 N/A All set-ups TRUE 0 Uint32
8-9* Bus Jog / Feedback
8-90 Bus Jog 1 Speed 100 RPM All set-ups TRUE 67 Uint16
8-91 Bus Jog 2 Speed 200 RPM All set-ups TRUE 67 Uint16
8-94 Bus Feedback 1 0 N/A 1 set-up TRUE 0 N2
8-95 Bus Feedback 2 0 N/A 1 set-up TRUE 0 N2
8-96 Bus Feedback 3 0 N/A 1 set-up TRUE 0 N2
5.1.10 9-** Probus
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
9-15 PCD Write Conguration ExpressionLimit 2 set-ups TRUE - Uint16
9-16 PCD Read Conguration ExpressionLimit 2 set-ups TRUE - Uint16
9-18 Node Address 126 N/A 1 set-up TRUE 0 Uint8
9-22 Telegram Selection [108] PPO 8 1 set-up TRUE - Uint8
9-23 Parameters for Signals 0 All set-ups TRUE - Uint16
9-27 Parameter Edit [1] Enabled 2 set-ups FALSE - Uint16
9-28 Process Control
[1] Enable cyclic
master 2 set-ups FALSE - Uint8
9-53 Probus Warning Word 0 N/A All set-ups TRUE 0 V2
9-63 Actual Baud Rate
[255] No baudrate
found All set-ups TRUE - Uint8
9-65 Prole Number 0 N/A All set-ups TRUE 0 OctStr[2]
9-70 Programming Set-up [9] Active Set-up All set-ups TRUE - Uint8
9-71 Probus Save Data Values [0] O All set-ups TRUE - Uint8
9-72 ProbusDriveReset [0] No action 1 set-up FALSE - Uint8
9-80 Dened Parameters (1) 0 N/A All set-ups FALSE 0 Uint16
9-81 Dened Parameters (2) 0 N/A All set-ups FALSE 0 Uint16
9-82 Dened Parameters (3) 0 N/A All set-ups FALSE 0 Uint16
9-83 Dened Parameters (4) 0 N/A All set-ups FALSE 0 Uint16
9-90 Changed Parameters (1) 0 N/A All set-ups FALSE 0 Uint16
9-91 Changed Parameters (2) 0 N/A All set-ups FALSE 0 Uint16
9-92 Changed Parameters (3) 0 N/A All set-ups FALSE 0 Uint16
9-94 Changed Parameters (5) 0 N/A All set-ups FALSE 0 Uint16
Parameter Lists Programming Guide
MG11CE02 Danfoss A/S © 03/2015 All rights reserved. 231