PVB 128/PVB 16 valve stack dimensions, mm [in] (continued)
Number
of PVB
128
(down)
Number of PVB 16
1 2 3 4 5 6 7 8 9 10 11
6 L1 503
[19.80]
543
[21.38]
583
[22.95]
L2 637,5
[25.10]
673,5
[26.52]
722,5
[28.44]
L3 428,5 [16.87]
7 L1 569
[22.40]
609
[23.98]
L2 697,5
[27.46]
746,5
[29.39]
L3 494,5 [19.47]
Weight for a PVG 128/16 valve stack
The combined weight of a PVG 128/16 valve stack can be defined like this:
(Numbers of PVB 128 x 16.9) + (numbers of PVB 16 x 3,67) + 17.5 = Weight in kg
(Numbers of PVB 128 x 37.26) + (numbers of PVB 16 x 8.09) + 38.6 = Weight in lb
Technical Information
PVG 16 Proportional Valve Group
PVG 16 Combinations Valve Stack Dimensions
©
Danfoss | December 2018 BC00000211en-000901 | 105