Fault Reaction Overview
Description Monitoring LED Solenoid valves Error pin output Reaction time
(ms)
Spool not at setpoint Passive High 250
Unable to reach float position Passive High 250
U
DC
> max. Passive Disabled 250
U
DC
< min. Passive ——————— Disabled 250
U
S
out of range Passive High 250
LVDT error Passive High 250
Temp > max. Passive Disabled High 250
Technical Information
PVG 16 Proportional Valve Group
Fault Monitoring and Reaction
©
Danfoss | December 2018 BC00000211en-000901 | 85