Compensated PVB
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The Compensated PVB features:
Integrated LS shuttle network
Integrated compensator
Compensated PVB schematic
1
0
2
A
Pp
T0
LX
P
T
B
Technical specification for A/B-port
Max. continuous pressure Max. intermittent pressure Max. rated flow
350 bar [5067 psi] 420 bar [6090 psi] 60 l/min [15 US gal/min]
Technical specification
Parameter Minimum Recommended range Maximum
Fluid temperature
-30°C [-22°F] 30 to 60°C [86 to 140°F] 90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS] 12 to 75 mm
2
/s [65 to 347 SUS] 460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG 16 Proportional Valve Group
PVB Basic Modules
©
Danfoss | December 2018 BC00000211en-000901 | 39

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals