The main spools (PVBS) determine the flow out of the work section or the pressure build up and are
based on a generic platform with a wide selection of additional features, enabling you to tailor the PVBS
to suit the demands of any hydraulic system and any function.
The PVBS main spool can be activated in three different ways:
Mechanically by a PVM lever
Electrically by a PVE/PVHC actuator
Hydraulically by a PVH actuator
PVBS main spool
PVBS main spool dimensions
110 [4.33]
14.8 [0.59]
46 [1.81]
Weight: 0.16 kg [0.35 lb]
General features
4-way, positions
Optional 4-way, 4 positions with the right PVM
Flow control AB
Dead band 1.2mm [0.047 in]
PVBS Technical Parameters
Technical specification
Parameter Minimum Recommended range Maximum
Fluid temperature
-30°C [-22°F] 30 to 60°C [86 to 140°F] 90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS] 12 to 75 mm
2
/s [65 to 347 SUS] 460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG 16 Proportional Valve Group
PVBS Main Spools
62 |
©
Danfoss | December 2018 BC00000211en-000901

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals