PVM torque data
Spool displacement
PVM+PVMD
PVM+PVE
PVM+PVH
From neutral position
2.2 ± 0.2 N•m
[19.5 ± 1.8 lb•in]
2.7 ± 0.2 N•m
[23.9 ± 1.8 lb•in]
Max. spool travel
2.8 ± 0.2 N•m
[24.8 ± 1.8 lb•in]
7.1 ± 0.2 N•m
[62.8 ± 1.8 lb•in]
Part numbers for PVM Manual Actuation
Part number Float Adjustment screws Lever base and lever Weight
11107332
Yes Yes
0,22 kg
[0,49 lb]
11107333
Yes
11107335
Yes Yes
11107505
11107506
Yes
11107507
Yes
PVMD Cover
The PVMD cover is used when work section is purely mechanical activated.
PVMD Cover Dimensions, mm [in]
86 [3.39]
39 [1.54]
14 [0.55]
Part number and weight for PVMD Cover
Part number 11105518
Weight 1.5 kg [3.3 lb]
Technical Information
PVG 16 Proportional Valve Group
PVG 16 Actuation
70 |
©
Danfoss | December 2018 BC00000211en-000901

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals