EasyManuals Logo

Danfoss Series 42 Service Manual

Danfoss Series 42
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Removal
1. Clean the exterior of the pump.
2. Remove any hoses or piping from the filter adapter.
3. Using a T30 Torx driver or 5 mm internal hex, remove the six screws (R042) securing the filter adapter
to the housing.
4. Remove the filter adapter (R040).
Housing without filtration adapter
R045
G004
5/8 in
37 N•m
[27 lbf•ft]
P108 091E
Suction Filtration Only
5. Remove the gasket (R041) and discard. Thoroughly clean all mating surfaces.
Replacement
1. Install a new gasket (R041) and place the filter adapter (R040) on the housing.
2. Using a T30 Torx driver or 5 mm internal hex, install bolts (R042) and torque to 17 N•m [13 lbf•ft].
Bolt torque patterns
1
2
3
4
5
6
7
8
Torque this bolt
first and last
TORQUE BOLTS IN THE ORDER INDICATED
Auxiliary pad/charge pump cover
Use the following procedure to install a new gasket (U030) or to change the auxiliary pad option. Pads are
available for SAE A and SAE B auxiliary pumps, or for options with no auxiliary pad.
The charge pump cover integrates the auxiliary mounting pad. When no auxiliary pump is present on an
SAE A or SAE B style pad, the pad includes a shipping plate (U085) and O-ring (U080).
Service Manual
Series 42 Axial Piston Closed Circuit Pumps
Minor Repair
520L0638 • Rev 0300July 2015 55

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Series 42 and is the answer not in the manual?

Danfoss Series 42 Specifications

General IconGeneral
BrandDanfoss
ModelSeries 42
CategoryWater Pump
LanguageEnglish

Related product manuals