EasyManuals Logo

Danfoss Series 42 Service Manual

Danfoss Series 42
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Loop flushing valve and loop flushing defeat components
Q060
/ in
27 N•m
[20 lbf•ft]
5
8
Q060A
Q061
Q062
Q050
/ in
37 N•m
[27 lbf•ft]
11
16
Q050A
Q051
Q051
Q050A
P108 105E
Loop flushing valve
1. Remove the loop flushing plug (Q050). Discard the O-ring (Q050A).
2. Remove the loop flushing spool assembly (Q051) from the housing.
3. Inspect the parts for damage or foreign material. Ensure the washer securely retains the centering
spring.
4. Install the loop flushing valve spool assembly (Q051) into its bore. Install a new Oring (Q050A) on the
loop flushing plug (Q050); torque to 37 N•m [27 lbf•ft].
Loop flushing relief valve
Two styles of loop flushing relief valve plugs exist. The style of plug is depends on the charge pressure
specification. If the charge pressure is greater than or equal to 18 bar [260 psi]: the plug has two
identification grooves. If the charge pressure is less than 18 bar [260 psi]: the plug has a single
identification groove.
Service Manual
Series 42 Axial Piston Closed Circuit Pumps
Minor Repair
520L0638 • Rev 0300July 2015 63