Allowable overhung load moment values are shown in the following table.
Allowable overhung load moments
Frame size Rated moment (MR) Shock load moment (MS)
N•m lbf•in N•m lbf•in
042 860 7600 3020 26 700
055 1580 14 000 5650 50 000
075 1580 14 000 5650 50 000
100 1580 14 000 5650 50 000
130 3160 28 000 10 730 95 000
180 6070 54 000 20 600 182 000
250 6070 54 000 20 600 182 000
Technical Information Series 90 Axial Piston Pumps
System Design Parameters
20 520L0603 • Rev 0804March 2016