EasyManua.ls Logo

Danfoss VACON 100 industrial - Power Ratings of VACON 100 FLOW, 208-240

Danfoss VACON 100 industrial
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.6.5 Power Ratings of VACON® 100 FLOW, 208–240 V
Table 35: Power Ratings of VACON
®
100 FLOW, Mains Voltage 208–240 V, 50–60 Hz, 3~
Enclo-
sure
size
Drive type
(1)
Low loadability:
Continuous cur-
rent I
L
[A]
(2)
Low loada-
bility: Input
current I
in
[A]
(2)
Low loadabili-
ty: 10% over-
load current
[A]
(2)
Low loadabil-
ity: Max cur-
rent I
s
2 s
(2)
Motor shaft
power
(3)
: 10%
overload 40°C
[kW]
Motor shaft
power
(3)
:
10% over-
load 40°C
[hp]
MR4 0003 3.7 3.2 4.1 5.2 0.55 0.75
0004 4.8 4.2 5.3 7.4 0.75 1.0
0007 6.6 6.0 7.3 9.6 1.1 1.5
0008 8.0 7.2 8.8 13.2 1.5 2.0
0011 11.0 9.7 12.1 16.0 2.2 3.0
0012 12.5 10.9 13.8 19.6 3.0 4.0
MR5 0018 18.0 16.1 19.8 25.0 4.0 5.0
0024 24.0 21.7 26.4 36.0 5.5 7.5
0031 31.0 27.7 34.1 46.0 7.5 10.0
MR6 0048 48.0 43.8 52.8 62.0 11.0 15.0
0062 62.0 57.0 68.2 96.0 15.0 20.0
MR7 0075 75.0 69.0 82.5 124.0 18.5 25.0
0088 88.0 82.1 96.8 150.0 22.0 30.0
0105 105.0 99.0 115.5 176.0 30.0 40.0
MR8 0140 143.0 135.1 154.0 210.0 37.0 50.0
0170 170.0 162.0 187.0 280.0 45.0 60.0
0205 208.0 200.0 225.5 340.0 55.0 75.0
MR9A 0261 261.0 253.0 287.1 410.0 75.0 100.0
0310 310.0 301.0 341.0 502.0 90.0 125.0
1
The currents in given ambient temperatures are achieved only when the switching frequency is the same or smaller than the factory default
2
See 10.7 Overload Capability.
3
230 V
If the process includes a cyclical load, for example if there are lifts or winches, speak to the manufacturer to get the dimensioning
information.
Specifications
Operating Guide | VACON® 100 Wall-mounted Drives
AQ298036140958en-000101 / DPD01711| 119
Danfoss A/S © 2019.05

Table of Contents

Related product manuals