10.6.9 Power Ratings of VACON® 100 HVAC, 208–240 V
Table 39: Power Ratings of VACON
®
100 HVAC, Mains Voltage 208–240 V, 50–60 Hz, 3~
Enclo-
sure
size
Drive type
(1)
Low Loadability:
Continuous current
I
L
[A]
(2)
Low Loadability:
Input current I
in
[A]
(2)
Low Loadabili-
ty: 10% over-
load current [A]
(2)
Motor shaft power
(3)
: 10% overload
40°C [kW]
Motor shaft
power
(3)
: 10%
overload 40°C
[hp]
MR4 0003 3.7 3.2 4.1 0.55 0.75
0004 4.8 4.2 5.3 0.75 1.0
0007 6.6 6.0 7.3 1.1 1.5
0008 8.0 7.2 8.8 1.5 2.0
0011 11.0 9.7 12.1 2.2 3.0
0012 12.5 10.9 13.8 3.0 4.0
MR5 0018 18.0 16.1 19.8 4.0 5.0
0024 24.2 21.7 26.4 5.5 7.5
0031 31.0 27.7 34.1 7.5 10.0
MR6 0048 48.0 43.8 52.8 11.0 15.0
0062 62.0 57.0 68.2 15.0 20.0
MR7 0075 75.0 69.0 82.5 18.5 25.0
0088 88.0 82.1 96.8 22.0 30.0
0105 105.0 99.0 115.5 30.0 40.0
MR8 0140 143.0 135.1 154.0 37.0 50.0
0170 170.0 162.0 187.0 45.0 60.0
0205 208.0 200.0 225.5 55.0 75.0
MR9A 0261 261.0 253.0 287.1 75.0 100.0
0310 310.0 301.0 341.0 90.0 125.0
1
The currents in given ambient temperatures are achieved only when the switching frequency is the same or smaller than the factory default.
2
See 10.7 Overload Capability.
3
230 V