Example:
The code can have this format, for example:
• VACON0100-3L-0061-5+IP54
• VACON0100-3L-0061-5-FLOW
Table 2: Description of the Type Code
Code Description
VACON0100
The product family: VACON0100 = the VACON
®
100 product family
3L Input/Function: 3L = A 3-phase input
0061 The drive rating in amperes. For example, 0061 = 61 A
5 The mains voltage:
2 = 208–240 V
5 = 380–500 V
6 = 525–600 V
7 = 525–690 V
FLOW The product:
(empty) = The VACON
®
100 INDUSTRIAL AC drive
FLOW = The VACON
®
100 FLOW AC drive
HVAC = The VACON
®
100 HVAC AC drive
+IP54 The optional codes. There are many options, for example +IP54 (an AC drive with the protection rating IP54).
3.4 Enclosure Sizes
The codes for nominal current and nominal mains voltage are part of the type code (see 3.3 Description of the Type Code) on the
package label (see 3.2 Package Label). Use these values to find out the enclosure size of the AC drive from the table.
In the example "VACON0100-3L-0061-5+IP54", the code for nominal current is 0003 and the code for nominal mains voltage is 5.