9-63 Actual Baud Rate
Option: Function:
[7] 3000 kbit/s
[8] 6000 kbit/s
[9] 12000 kbit/s
[10] 31,25 kbit/s
[11] 45,45 kbit/s
[255] * No baudrate
found
9-64 Device Identication
Range: Function:
0* [0 - 0 ] Device identication parameter.
9-65 Prole Number
Range: Function:
0* [0 - 0 ] This parameter contains the prole
identication. Byte 1 contains the
prole number and byte 2 the
version number of the prole.
9-67 Control Word 1
Range: Function:
0* [0 - 65535 ] This parameter accepts the control
word from a master class 2 in the
same format as PCD 1.
9-68 Status Word 1
Range: Function:
0* [0 - 65535 ] This parameter delivers the status
word for a master class 2 in the
same format as PCD 2.
9-70 Programming Set-up
This parameter is unique for LCP and eldbus. See
parameter 0-11 Programming Set-up.
Option: Function:
Select the set-up to edit.
[0] Factory setup Uses default data. This option can
be used as a data source to return
the other set-ups to a known state.
[1] Set-up 1 Edits set-up 1.
[2] Set-up 2 Edits set-up 2.
[3] Set-up 3 Edits set-up 3.
[4] Set-up 4 Edits set-up 4.
[9] * Active Set-up Follows the active set-up selected
in parameter 0-10 Active Set-up.
9-71 Probus Save Data Values
Option: Function:
Parameter values changed via
PROFINET are not automatically
stored in the non-volatile memory.
Use this parameter to activate a
function that stores parameter
values in the EEPROM non-volatile
memory, so changed parameter
values are retained at power-down.
[0] * O Deactivate the non-volatile storage
function.
[1] Store all
setups
Store all parameter values for all
set-ups in the non-volatile memory.
When all parameter values have
been stored, the selection returns
to [0] O.
[2] Store all
setups
Store all parameter values for all
set-ups in the non-volatile memory.
When all parameter values have
been stored, the selection returns
to [0] O.
9-72 ProbusDriveReset
Option: Function:
[0] * No action
[1] Power-on
reset
Reset frequency converter upon
power-up, as for power cycle.
[2] Power-on
reset prep
Prepare for resetting frequency
converter upon power-up.
[3] Comm option
reset
Reset the PROFINET option only,
the PROFINET option goes through
a power-up sequence.
When reset, the frequency
converter disappears from the
eldbus, which may cause a
communication error from the
master.
9-75 DO Identication
Range: Function:
0* [0 - 65535 ] Provides information about the DO
(Drive Object).
9-80 Dened Parameters (1)
Array [116]
No LCP access
Read only
Range: Function:
0* [0 - 9999 ] This parameter shows a list of all
the dened frequency converter
parameters available for PROFINET.
Parameter Descriptions VLT® AutomationDrive FC 361
110 Danfoss A/S © 03/2019 All rights reserved. MG06J202
44

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 361

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 361 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 361 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 361
CategoryDC Drives
LanguageEnglish

Related product manuals