Message Description
e30bd118.11
Safety Password
Please enter the safety
Password
1(1)
0 RPM None
00000000
If selecting [VLT:…] and the password protection in parameter 0-69 Password Protection of Safety
Parameters is enabled, enter the correct LCP-copy/parameter mismatch password (parameter 0-68
Safety Parameters Password).
e30bd119.11
1(1)
0 RPM None
Password accepted
Pa
0-
[0
([1] Enabled)
If the entered password is correct, this overlay message is shown for some seconds.
e30bd123.11
1(1)
0 RPM None
Password rejected
Pa
0-
[0
([1] Enabled)
If the entered password is wrong, this overlay message is shown for some seconds. Then the pass-
word can be entered again.
e30bd120.11
SO Data Confirmation
Are you sure that you want
to overwrite the safety
parameters including the
level 1 password?
!1(1)
0 RPM 0.00A
e30bd121.11
SO Data Confirmation
Press [OK] to confirm
(commissioning test must be
performed) or [CANCEL] to
abort
!1(1)
0 RPM 0.00A
Decision box for continuing overwriting the existing data or to abort the procedure.
e30bd122.11
Status
SO Custom. completed
SO RESET required!
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
Off Remote SO Req.RESET
Press [OK] to complete the customization of the safety option. A reset is required to finalize this
procedure.
Service and Repair
Installation Guide | VLT® Safety Option MCB 150/151
AQ279747441421en-000101 / 130R0292 | 73