3.5.3.2 Fork Lift Transport and Lifting
WARNING
HEAVY LOAD!
Unbalanced loads can fall and loads can tip over. Failure to take proper lifting precautions increases risk of death,
serious injury, or equipment damage.
Never walk under suspended loads and wear personal protective equipment.
Make sure to use lifting devices with the appropriate rating.
The center of gravity can be in an unexpected area. If that is not observed, the unit can fall over or tilt
unexpectedly during lifting and transport. Check the center of gravity, before lifting the load. Refer to
Illustration 5.1, Illustration 5.2, and Illustration 5.3.
Secure cabinets by suitable means to prevent them from tipping over, particularly during transportation.
When using a pedestal/plinth or Flex-Block system during transportation, lifting, and setting down, ensure that
the load is always resting on the pedestal/plinth corner pieces and never on the base/plinth trim panels.
Do not use fork lifts for units which do not t on a transport pallet or the fully extended forks.
Make sure that the unit has a rm stand on the pallet or the forks, so that it would not fall over.
Make sure that the forks are placed under the base/plinth corner pieces and not on the base/plinth trim
panels.
max. 1400 kg
(3086 lbs.)
130BE491.10
Illustration 3.6 Approved Procedure for Fork Lift Transport of a
Single Enclosure
130BE489.10
Illustration 3.7 Non-approved Procedure for Fork Lift Transport
of a Single Enclosure
Mechanical Installation Installation Guide
MG13B102 Danfoss A/S © 09/2015 All rights reserved. 17
3 3

Other manuals for Danfoss VLT series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT series and is the answer not in the manual?

Danfoss VLT series Specifications

General IconGeneral
SeriesVLT
CategoryDC Drives
Output Voltage0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesProfibus, CANopen
Enclosure RatingIP20, IP21, IP55, IP66
Cooling MethodForced Air Cooling, Convection Cooling
Control ModeSensorless Vector, Closed Loop Vector
Ambient Temperature-10°C to +50°C (14°F to 122°F)

Related product manuals