5 General Specications
5.1 Mains Supply
Mains supply (L1-1, L2-1, L3-1, L1-2, L2-2, L3-2)
Supply voltage 380–500 V ±10%
Supply voltage 525–690 V ±10%
Mains voltage low/mains drop-out:
During low mains voltage or a mains drop-out, the frequency converter continues until the DC-link voltage drops below the
minimum stop level, which corresponds typically to 15% below the lowest rated supply voltage. Power-up and full torque cannot
be expected at mains voltage lower than 10% below the lowest rated supply voltage.
Supply frequency 50/60 Hz ±5%
Maximum imbalance temporary between mains phases 3.0% of rated supply voltage
True power factor (λ) ≥0.9 nominal at rated load
Displacement power factor (cos ϕ) near unity (>0.98)
Switching on input supply L1-1, L2-1, L3-1, L1-2, L2-2, L3-2 (power-ups) Maximum 1 time/2 minutes
Environment according to EN 60664-1 Overvoltage category III/pollution degree 2
The unit is suitable for use on a circuit capable of delivering not more than 100000 RMS symmetrical Amperes, 500/600/690 V
maximum.
5.2 Motor Output and Motor Data
Motor output (U, V, W)
Output voltage 0–100% of supply voltage
Output frequency 0–590 Hz
Switching on output Unlimited
Ramp times 0.001–3600 s
Torque characteristics
Starting torque (constant torque) Maximum 150% for 60 s
1)
once in 10 minutes
Starting/overload torque (variable torque) Maximum 110% up to 0.5 s
1)
once in 10 minutes
Torque rise time in FLUX (for 5 kHz fsw) 1 ms
Torque rise time in VVC
+
(independent of fsw) 10 ms
1) Percentage relates to the nominal torque.
2) The torque response time depends on application and load but as a rule, the torque step from 0 to reference is 4–5 x torque
rise time.
5.3 Ambient Conditions
Surroundings
Enclosure IP21/Type 1, IP54/Type 12
Vibration test 0.7 g
Maximum relative humidity 5–95% (IEC 721-3-3; Class 3K3 (non-condensing)) during operation
Aggressive environment (IEC 60068-2-43 Class H
2
5
Ambient temperature (with SFAVM switching mode)
- with derating Maximum 55 °C (131 °F)
1)
- at full continuous frequency converter output current Maximum 45 °C (113 °F)
1)
1) For more information on derating, see special conditions in the VLT
®
AutomationDrive FC 301/FC 302 Design Guide
Minimum ambient temperature during full-scale operation 0 °C (32 °F)
Minimum ambient temperature at reduced performance -10 °C (14 °F)
Temperature during storage/transport -25 to +65/70 °C (8.6 to 149/158 °F)
Maximum altitude above sea level without derating 1000 m (3281 ft)
Derating for high altitude, see special conditions in the VLT
®
AutomationDrive FC 301/FC 302 Design Guide
General Specications Operating Instructions
MG34Q402 Danfoss A/S © 04/2016 All rights reserved. 71
5 5

Table of Contents

Other manuals for Danfoss VLT series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT series and is the answer not in the manual?

Danfoss VLT series Specifications

General IconGeneral
SeriesVLT
CategoryDC Drives
Output Voltage0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesProfibus, CANopen
Enclosure RatingIP20, IP21, IP55, IP66
Cooling MethodForced Air Cooling, Convection Cooling
Control ModeSensorless Vector, Closed Loop Vector
Ambient Temperature-10°C to +50°C (14°F to 122°F)