Enter/Exit Programming Mode
Product Reference Guide
115
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments. See page 298 in “References” for detailed
information on setting this feature.
$CSNFN
Select Flash ON Time Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad
representing
your desired character(s). End by scanning the
ENTE
R/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code t
o abort
and not save the entry string. You can then start again
at the beginning.
~
CANCEL
DEFAULT
10 = Flash is ON for 1 Second
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash
Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 sec-
onds), in 100 millisecond increments. See page 299 in “References” for
detailed information on setting this feature.
$CSNFF
Select Flash OFF Time Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad
representing
your desired character(s). End by scanning the
ENTE
R/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code t
o abort
and not save the entry string. You can then start again
at the beginning.
~
CANCEL
DEFAULT
06 = Flash is OFF for 600ms

Table of Contents

Other manuals for Datalogic Gryphon I GD4400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon I GD4400 and is the answer not in the manual?

Datalogic Gryphon I GD4400 Specifications

General IconGeneral
Environmental SealingIP52
Dimensions18.1 x 7.1 x 10.0 cm / 7.1 x 2.8 x 3.9 in
Connectivity TechnologyWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-20 to 70 °C / -4 to 158 °F
Ambient Light Immunity0 to 100, 000 lux
ESD Protection16 kV
InterfaceUSB, RS-232, Keyboard Wedge, IBM 46XX
Resolution4 mils
Drop ResistanceWithstands drops from 1.8 m / 5.9 ft to concrete
Weight195 g / 6.88 oz
Decode Capability1D Codes, 2D Codes, Postal Codes, Stacked Codes
Scan RateUp to 60 frames per second