1D Code Selection Enter/Exit Programming Mode
Product Reference Guide
197
GS1 DataBar™ Expanded 2D Component
This feature enables/disables a requirement that a 2D label component be
decoded when a base label of this symbology is decoded.
DEFAULT
$CXB2D00(CR)
GS1 DataBar™ Expanded 2D Component = Disable
$CXB2D01(CR)
GS1 DataBar™ Expanded 2D Component = Enable
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the GS1 DataBar™ Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
DEFAULT
$CXBLC00(CR)
GS1 DataBar™ Expanded Length Control = Variable Length
$CXBLC01(CR)
GS1 DataBar™ Expanded Length Control = Fixed Length