SOFTWARE CONFIGURATION
46
Example: to have a Data Packet composed of Code Data followed by the ISO/IEC 15415
code quality parameters (grade only) in parenthesis, separated by a comma and a space, the
Data Packet Format string must be the following:
Data Packet Format = %2 (%C, %E, %I, %K, %a, %m, %Q, %n)
The transmitted code quality parameters have the following format:
• 1 character for code quality parameters expressed as grade (i.e. A,B,C,D,F or P,F)
• 1 character for code quality parameters expressed as numeric value corresponding to a
grade (0,1,2,3,4).
• 4 numeric characters for code quality parameters expressed as percentage including dot
(example: 78% → 0.78).
• 3 numeric characters for AS9132A Angle Of Distortion parameter (example: 3° → 003).
When
ISO/IEC 16022-18004 Status parameter is enabled, the following code quality
parameters can be included in the Data Packet Format string:
• %C
ISO-IEC / AIM DPM Overall (Grade)
• %D
ISO-IEC / AIM DPM Overall (Value)
• %E
ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (grade)
• %F
ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (value)
• %G
ISO-IEC / AIM DPM Print Growth (grade)
• %H
ISO-IEC / AIM DPM Print Growth (value)
• %I
ISO-IEC / AIM DPM Axial Non Uniformity (grade)
• %J
ISO-IEC / AIM DPM Axial Non Uniformity (value)
• %K
ISO-IEC / AIM DPM Unused ECC (grade)
ISO-IEC / AIM DPM Unused ECC (value)
• %L
When
ISO/IEC 15415 Status parameter is enabled, the following code quality parameters
can be included in the Data Packet Format string:
• %C
ISO-IEC / AIM DPM Overall (Grade)
• %D
ISO-IEC / AIM DPM Overall (Value)
• %E
ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (grade)
• %F
ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (value)
• %H
ISO-IEC / AIM DPM Print Growth (value)
• %I
ISO-IEC / AIM DPM Axial Non Uniformity (grade)
• %J
ISO-IEC / AIM DPM Axial Non Uniformity (value)
• %K
ISO-IEC / AIM DPM Unused ECC (grade)
• %L
ISO-IEC / AIM DPM Unused ECC (value)
• %a
ISO-IEC / AIM DPM Decode (Grade)
• %Q
ISO-IEC Modulation / AIM DPM Cell Modulation (grade)
• %R
ISO-IEC Modulation / AIM DPM Cell Modulation (value)
• %m
ISO-IEC / AIM DPM Fixed Pattern Damage (grade)
• %W
ISO-IEC / AIM DPM Fixed Pattern Damage (value)
• %n
ISO-IEC / AIM DPM Grid Non Uniformity (grade)
• %X
ISO-IEC / AIM DPM Grid Non Uniformity (value)
69