116
RF EXPOSURE INFORMATION (SAR)
This model device meets the government’s requirements for exposure to radio
waves. This device is designed and manufactured not to exceed the emission limits
for exposure to radio frequency (RF) energy set by the Federal Communications
Commission of the U.S. Government.
The exposure standard for wireless devices employs a unit of measurement known
as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg.
Tests for SAR are conducted using standard operating positions accepted by the
FCC with the device transmitting at its highest certified power level in all tested
frequency bands. Although the SAR is determined at the highest certified power
level, the actual SAR level of the device while operating can be well below the
maximum value. This is because the device is designed to operate at multiple power
levels so as to use only the poser required to reach the network. In general, the
closer you are to a wireless base station antenna, the lower the power output.
The highest SAR value for the model device as reported to the FCC are the
following:
- DL-Memor + 802.11 + BT models: for use at the head is 1.32 W/Kg and when
worn on the body, as described in the user guide, is 0.518 W/Kg. (Body-worn
measurements differ among device models, depending upon available
enhancements and FCC requirements).
While there may be differences between the SAR levels of various devices and at
various positions, they all meet the government requirement.
The FCC has granted an Equipment Authorization for this model device with all
reported SAR levels evaluated as in compliance with the FCC RF exposure
guidelines. SAR information on this model device is on file with the FCC and can be
found under the Display Grant section of http://www.fcc.gov/oet/fccid after searching
on the below FCC ID:
FCC ID: U4GA030 for DL-Memor+802.11+BT models.
This device is compliant with SAR for general population /uncontrolled exposure
limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the
measurement methods and procedures specified in OET Bulletin 65 Supplement C.
For body worn operation, this device has been tested and meets the FCC RF
exposure guidelines for use with an accessory that contains no metal and the
positions the handset a minimum of 1.5 cm from the body. Use of other
enhancements may not ensure compliance with FCC RF exposure guidelines. If you
do not use a body-worn accessory and are not holding the device at the ear, position
the handset a minimum of 1.5 cm from your body when the device is switched on.

Table of Contents

Other manuals for Datalogic Memor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Memor and is the answer not in the manual?

Datalogic Memor Specifications

General IconGeneral
Scan speed104 sec/page
Wavelength630 nm
Sensor typeLaser
Decoding standardsUPC A, UPC E, EAN 8, EAN 13, Code 39, Code 39 Full ASCII, Code 32, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Code 128, EAN 128, Codabar, MSI, Plessey, Code 93, Code 11, GS1 Databar.
Product colorBlack
Internal memory256 MB
Built-in processorPXA310
Display resolution240 x 320 pixels
Processor frequency624 MHz
BluetoothYes
Standard interfacesUSB, RS-232
Battery typeLi-polymer/Li-ion
Input voltage5 V
Power consumption1100 mA
SafetyClass 2
DisplayReflective TFT 64K
Dimensions (WxDxH)152 x 55 x 40 mm
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Weight230 g