EasyManuals Logo

Datalogic PowerScan 9500 Series User Manual

Datalogic PowerScan 9500 Series
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
Enter/Exit Programming Mode
126
PowerScan™ PD9530/PBT9500/PM9500
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for I 2 of 5 Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The l
ength includes the bar code’s
check and data characters. The length can be set from 2 to 50 characters in
increments of two.
Table 8 provides some examples for setting Length 1. See page 267 for
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Characters 6 Characters 14 Characters 50 Characters
2
Pad with leading zeroes to
yield tw
o digits
02 06 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘2’ ‘0’ and ‘6’ ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan 9500 Series and is the answer not in the manual?

Datalogic PowerScan 9500 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan 9500 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals