Enter/Exit Programming Mode
Product Reference Guide
73
Stand Mode Sensitivity
Sets the sensitivity level for stand mode wakeup. Choices are low, medium
and high.
$CSMSE00(CR)
Stand Mode Sensitivity = Low
$CSMSE01(CR)
Stand Mode Sensitivity = Medium
DEFAULT
$CSMSE02(CR)
Stand Mode Sensitivity = High
Stand Mode Illumination Off Time
Specifies the amount of time reader illumination stays off after pulling the
trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in
increments of 500ms (500ms to 16 seconds). See
page 280 in “References”
for a description of this feature.
$CSNTM
Select Stand Mode Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER
/EXIT bar code again.
DEFAULT
04 = 2 Seconds