Using the SC6000 keypad:
1. Press the <Ent> and <Menu> keys simultaneously to enter the Menu;
2. Use the <arrow> keys to move within the menu items;
3. In the <System> menu choose <Backup> and select the desired backup option
(complete, all scanners, controller).
The SC6000 Controller will store the complete system configuration on the Compact Flash
card.
If a slave scanner has to be replaced, the corresponding configuration (node address, code
configuration, PackTrack™ configuration, etc.) is automatically downloaded by the SC6000
into the new scanner at the next system startup.
If the SC6000 controller replaces an SC8000 controller within the network,
(Topology Role parameter = Other; Device Assignment parameter =
Controller Lon SC8000), refer to the "Replacing SC8000 with SC6000-
PWO.pdf" document for details.