EasyManuals Logo

Datamax A-4310 User Manual

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Extended System-Level Command Functions
Class Series Programmer’s Manual 47
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
End Of Print
EP
1, 2, 3, 4
1 = Low Pulse,
2 = High Pulse,
3 = Active Low,
4 = Active High
Display-Equipped Printer Options N/A
Display-Equipped Communications
ESC Sequences
ES
Y, N
Y = Enabled,
N = Disabled
EX2 N/A
N/A
Exact Time
ET
Y, N
Y = Enabled,
N = Disabled
Non-Display (except
M1, M2, and EX2)
24 N/A
Display-Equipped System Settings
EX2 N/A
Fault Handling
FH
L, D, R, B See Table 5-2.
M1 & M2
Non-Display
24
N/A
Feed Speed
SS or sS
Alpha
character
Model specific ranges;
see Appendix L.
Display-Equipped Print Control
Sa
Display-Equipped Communications
Feedback Mode
FM
Y, N
Y = Enabled,
N = Disabled
EX2 N/A
<STX>a
Display
Font Emulation
FE
0, 1, 2
0 = No Substitution
1 = Sub CG Times SA0
2 = Sub User S50
Non-Display
N/A N/A
Table 5-1: Configuration Set Commands (continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-4310 and is the answer not in the manual?

Datamax A-4310 Specifications

General IconGeneral
BrandDatamax
ModelA-4310
CategoryPrinter
LanguageEnglish

Related product manuals