Extended System-Level Command Functions
Class Series Programmer’s Manual 47
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
End Of Print
EP
1, 2, 3, 4
1 = Low Pulse,
2 = High Pulse,
3 = Active Low,
4 = Active High
Display-Equipped Printer Options N/A
Display-Equipped Communications
ESC Sequences
ES
Y, N
Y = Enabled,
N = Disabled
EX2 N/A
N/A
Exact Time
ET
Y, N
Y = Enabled,
N = Disabled
Non-Display (except
M1, M2, and EX2)
24 N/A
Display-Equipped System Settings
EX2 N/A
Fault Handling
FH
L, D, R, B See Table 5-2.
M1 & M2
Non-Display
24
N/A
Feed Speed
SS or sS
Alpha
character
Model specific ranges;
see Appendix L.
Display-Equipped Print Control
Sa
Display-Equipped Communications
Feedback Mode
FM
Y, N
Y = Enabled,
N = Disabled
EX2 N/A
<STX>a
Display
Font Emulation
FE
0, 1, 2
0 = No Substitution
1 = Sub CG Times SA0
2 = Sub User S50
Non-Display
N/A N/A
Table 5-1: Configuration Set Commands (continued)